System Settings (3 of 3)
This screen shows Page 3 of the System settings.
The HMI and DSP firmware revisions can be seen on this screen.
Additionally the flowmeter parameters can be stored to internal memory. The saved parameters can be
used to restore the flowmeter's parameters in the event of memory loss or DSP board replacement.
Logging Parameters
This screen shows the Data Logging Parameters.
The log internal can be set using the numeric boxes under the data labels. The logging function can be set
to Run or Stop as well as the location to store the logged data (Internal vs. External). Note for External
data logging, a user supplied USB drive must be installed.
To export data to a user supplied USB drive, insert the USB drive, select the start and end dates, then press
Download.
The icons located in the upper right hand corner of the display shows various connectivity status. Reading
from left to right, the list below details the icons and what status they will show.
Initial Setup and General Operations 5-7
System Settings 3 of 3
Logging Parameters