driver is undamaged and properly calibrated and that you have been
trained in its use. You may wish to use a driver that is designed to prevent
overtorque when the preset torque level is achieved.
Replace the plastic cover over the terminals on the faceplate.
7.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
8.
the strap to an approved site ESD grounding point. See the instructions for your site.
Connect each DC power cable to the appropriate external DC power source.
9.
NOTE:
For information about connecting to external DC power sources,
see the instructions for your site.
Switch on the external circuit breakers to provide voltage to the DC power source
10.
cable leads. Observe the status LED on the power supply faceplate. If a DC power
supply is correctly installed and is functioning normally, the status LED lights green
steadily. If the status LED indicates that the power supply is not functioning normally,
repeat the cabling procedures.
Figure 8: Connecting DC Power to the Router