Automatic Compensation Of Neutral Point Of; Selection Of The Pedal Specifications - JUKI SC-922 Instruction Manual

Hide thumbs Also See for SC-922:
Table of Contents

Advertisement

~----------------------------~--
9.
Automatic compensation of neutral point of the pedal sensor
Whenever the pedal sensor, spring, etc. are replaced, be sure to perform following operation
·
1)
Pressing switch
~
0
,
turn ON
the
~
power
sw1tch.
2)
Compensated value is displayed
on
indicator
a .
(Caution)
1.
At
this time,
the pedal
sensor
does not work
properly if
the pedal is de-
pressed.
Warning sound
"
blips
"
and the correct
compensation
value is not
displayed.
2.
If
any
display
("·0·"
or
" -8-")
other than a nu·
merle
value appears on
Indicator
8,
refer to the
Engineer's Manual.
3)
Turn
OFF
the power switch, and turn
ON
the power switch again to return to the normal mode.
(Caution) Be
sure
to re-turn ON the power
switch
when one
or more seconds
have passed after turn-
Ing it
OFF.
(If the ON-OFF operation
is
carried out faster than the
above,
the
setting
may not change
normally.)
1 0. Selection of the pedal specifications
When the pedal sensor has been replaced, change
the
set value of function setting
No.
so
according
to
the
newly connected pedal specifications.
7
f)
0.
KFL
1:
PFL
A
c
0
n ,_,
(Caution)
-42-
Pedal sensor with two
springs
located at the back
part of the pedal type
Is
PFL
,
and that with
one
spring
type is
KFL.
Set
the
pedal sensor to PFL when
lifting the presser
toot
by
depressing the back part of
the pedal.

Advertisement

Table of Contents
loading

Table of Contents