Parameter
Function
No.
External Fault
Sn-20
Contact Selection
External Fault
Sn-21
External Fault
Sn-22
Protection
Charac-
Motor Overload
teristic.
Sn-23
Selection
Characteristics
Sn-24
Selection at
External Analog
Input Terminal
Multi-Function
Sn-25
Input Terminal
Function Selection
Multi-Function
Multi-
Sn-26
Input Terminal
function
Function Selection
Input
Multi-Function
Contact
Sn-27
Input Terminal
Selection
Function Selection
Multi-Function
Sn-28
Input Terminal
Function Selection
Multi-
Multi-Function
function
Analog Input
Analog
Sn-29
(AUX) Function
Input
Selection
LCD display
Name
(English)
Sn-20= 0
Contact
Term.3 NO_Cont.
Contact
Sn-21= 0
Detection
All Time Ext. Fault
Selection
Sn-22= 1
Operation
Ext. Fault Free run
Selection
Sn-23= 1
Protection
Cold Start Over Load
Selection
Frequency
Command
Sn-24= 0
~ Cmd. VIN
Sn-25= 02
Multi-Fun. Command1
Sn-26= 03
Multi-Fun. Command1
Sn-27= 06
Jog Command
Sn-28= 07
Acc. & Dec Switch 03~29
Sn-29= 00
Auxiliary Freq. Cmd. 00~12
Selection
Description
0 : A-contact (normally open input)
1 : B-contact (normally close input)
0 : detect all time
1 : detect only during operation
0 : dec. to stop (upon dec. time1 Bn-02)
1 : coast (free run) to stop
2 : dec. to stop (upon dec. time1 Bn-04)
3 : continue operating
Electronically motor overload
protection selection
0 : electronically motor overload
protection invalid
1 : standard motor cold start
overload protection characteristics
2 : standard motor hot start overload
protection characteristics
3 : special motor cold start overload
protection characteristics
4 : special motor hot start overload
protection characteristics
Frequency command characteristics
selection at external analog input
terminal
0 : voltage signal 0~10V (VIN)
1 : current signal 4~20mA (AIN)
2 : addition of voltage signal 0~10V
and current signal 4~20 mA
(VIN+AIN)
3 : subtraction of current signal
4~20mA and voltage signal
0~10V (VIN-AIN)
00~25 The factory setting is multi-
function command1
01~26 The factory setting is multi-
function command2
02~27 The factory setting is jog
command
The factory setting is Acc. &
Dec. Interrupt
Multi-function analog input
terminal (AUX) as Auxiliary
frequency command.
(factory setting)
64
Factory
Ref.
Page
Setting
0
78
0
78
1
78
1
79
0
79
02
03
80
06
07
00
88