C. Clearances to Combustibles
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters)
SINGLE WALL PIPE
DOUBLE WALL PIPE
INSTALLATION: 90 DEGREE ELBOW OFF TOP OF APPLIANCE THROUGH BACKWALL
DOUBLE WALL PIPE
SINGLE WALL PIPE
For alcove only: Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A
chimney or masonry chimney. Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced alcove
clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory built chimney.
ALCOVE SIDE VIEW
G
A
HORIZONTAL THROUGH WALL
TOP AND SIDE VIEW
40.5 in.
1029 mm
WARNING
Fire Risk
•
Comply with all minimum clearances to
combustibles as specified.
• Failure to comply may cause house fire.
November 29, 2016
Note: A, C, and F Dimensions are to the center of the flue collar
INSTALLATION: FULL VERTICAL
A
B
10-1/2 (267)
7 (178)
9-1/2 (241)
6 (153)
9-1/2 (241)
6 (153)
INSTALLATION: HORIZONTAL THROUGH THE WALL
N/A
N/A
43-1/2 (1105)
* FOLLOW PIPE MANUFACTURES CLEARANCES AS REQUIRED
ALCOVE TOP VIEW
MANTEL
12" MAX
52.5 in.
1334 mm
304.8mm
EXPLORER-III
C
D
27 (686)
12 (305)
7 (178)
27 (686)
12 (305)
5 (127)
27 (686)
12 (305)
N/A
25-1/2 (648)
N/A
C
12 in.
7060-228G
Explorer III Wood Stove
E
F
G
18 (457)
52-1/2 (1334)
16 (406)
52-1/2 (1334)
N/A
52.1/2 (1334)
N/A
52-1/2 (1334)
BACKWALL / SIDEWALL
C
A
B
D
CORNER INSTALLATION
F
E
APPLIANCE TO
G
CEILING
CLEARANCE
H*
N/A
N/A
18 (457)
N/A
H*
9