Installation

System Start-up: Step 1
Prepare the transmitter installation location. If the back of the transmitter is diffi cult to
access when installed, wire the removable terminal blocks fi rst, then install it completely.
For future reference, for each installation, it is recommended to record the part number
and serial number of each of the components listed here:
Facility Tag Number or System ID (user assigned):___________________
Base unit
Relay Module
Cond/Res Module
H COMM Module
Batch Module
4 to 20 mA Output Module
Panel Mount Installation
Tools and Equipment Required
● Fine-tooth fi le
● ¼ DIN punch or jigsaw suitable for cutting panel opening to within 1 mm (0.04 in) tolerance.
● ¼ DIN punches are available and recommended for creating clean, precise openings
quickly and easily in most instrument panels.
● If a punch is not available, a jigsaw or other cutting tool can be used.
An adhesive template is provided to help guide the cutting process.
De-burr and smooth the opening with a fi le.
1. The panel mount transmitter is designed for installation using a ¼ DIN punch.
Recommended clearance on all sides between instruments is 25 mm (1 in).
2. Place gasket on instrument, and install in panel.
3. Slide mounting bracket over back of instrument until bracket snaps into latches on
sides of instrument.
To remove:
1. Secure instrument temporarily with tape from front or grip from rear of instrument.
DO NOT RELEASE.
2. Press bracket clips outward and remove.
Field Mount Installation
Field mounting requires a separate mounting kit. The 3-8050 Universal Mount Kit, the
3-8051 or 3-8052 Integral Mount Kits, and the 3-9900.396 Angle Adjustment Adapter Kit
enable the transmitter to be installed virtually anywhere. Detailed instructions for fi eld
installation options are included with the 3-8050, 3-8051 and 3-8052 adapter kits
(see Ordering Information section).
For Field Mount installations with a Cond/Res Module, the 3-9900.396 Angle Adjustment
Adapter is required along with a 3-8050 or 3-8052 adapter kit to allow for suffi cient
clearance for the wiring.
Next step: Wiring (see page 8).
3-9900-____
S/N ___________________
3-9900.393
S/N ___________________
3-9900.394
S/N ___________________
3-9900.395
S/N ___________________
3-9900.397
S/N ___________________
3-9900.398-1
S/N ___________________
Do not mount in direct sunlight.
Panel Cutout
Panel Cutout
92 x 92 mm
92 x 92 mm
(+ 0.8, - 0 mm)
(+ 0.8, - 0 mm)
3.6 x 3.6 in.
3.6 x 3.6 in.
(+0.031, -0 in.)
(+0.031, -0 in.)
minimum
clearance
25 mm
(1 in.)
Panel Cutout
Panel Cutout
92 x 92 mm
92 x 92 mm
(+ 0.8, - 0 mm)
(+ 0.8, - 0 mm)
3.6 x 3.6 in.
3.6 x 3.6 in.
(+0.031, -0 in.)
(+0.031, -0 in.)
gasket on
front side
of panel
panel
terminal
blocks
Quick-clip
mounting
bracket
Field Mount with
3-8050 Universal Mount Kit
Field Mount with
3-8051 Integral Mount Kit
and Angle Adjustment Adapter
9900 Transmitter