Signet 9900 Operating Instructions Manual page 26

Table of Contents

Advertisement

Menu System
VIEW Mode Overview
The top level of menus is referred to as the VIEW Mode. This view displays measurement
values as well as current outputs and relay status. The radial bar graph represents the
measurement value that is also displayed in the 7-segment numeric fi eld below the bar
graph. The bar graph is primarily used to display the full scale range of the sensor, but can
be scaled via a menu item.
During normal operation, the 9900 displays the VIEW mode.
● To select a display, press the ▲ or ▼ arrow keys.
The display selections scroll in a continuous loop.
● Changing the display selection does not interrupt system operations.
● No password is necessary to change display selection.
● Output settings cannot be edited from the View Mode.
● The display will return to the VIEW mode if no button is pressed for 10 minutes.
MENU Mode Overview
The MENU mode enables the user to view and confi gure all menu items.
The fi ve menus available are: CAL, INPUT, LOOP, RELAY, and OPTION.
MENU Mode is entered by pressing and holding ENTER for three seconds.
The ► button is used to change the position of the blinking cursor.
When the desired menu is blinking, press ENTER.
In the selected menu, use the ▲ and ▼ keys to navigate through the menu.
Use the ▲, ▼ and ► keys to edit the selected item
(see Menu Navigation discussion, page 24).
To save the new selection, press the ENTER key. A message displaying "Saving..." will be
displayed for 3 seconds. After this message is displayed, the newly selected value will be
displayed, if applicable.
Password Overview
The password is often required to start editing. Once entered correctly, this password will
not be needed for subsequent edits. However, once the menu system is exited,
the password will again be required when edit mode is re-entered.
Your choice of password (STD or CODE) is selected in the Options Mode.
● STD
The standard (STD) password is ▲▲▲▼, pressed in sequence. This password is
designed to protect the 9900 from unintentional changes. It is best suited for systems
where a group of people need to be able to change settings.
● CODE
The CODE default setting is 0000, adjustable to any 4-digit numerical code up to
9999. Using a personal code provides the maximum degree of security.
This code can be modifi ed in the Options mode.
26
9900 Transmitter
Error Handling
Errors occurring while in the
VIEW Mode show a specifi c
message (e.g., CHECK SENSOR).
This message is displayed every
10 seconds and stays on for 5
seconds. Once the error is
resolved or cleared, the error
message stops.
Scrolling
In some cases, more than one
message or measurement may
need to be displayed. This is
accomplished by alternating the
message portions across the
screen.
In the MENU mode, if the
wrong code or password is
entered, an ERROR message
is displayed.
To change your CODE, go
to OPTIONS mode, enter
your desired code and press
ENTER. (The STD password
cannot be changed.)