Download Print this page

Innovo INV-DC200 Instruction Manual page 7

Dual mode digital infrared thermometer
Hide thumbs Also See for INV-DC200:

Advertisement

within 5 seconds to change the temperature
unit to your choice.
Error message
LCD screen will display "Er1" when ambient
temperature exceeds 104.0°F/40.0°C or
drops below 50.0°F/10.0°C.
LCD screen will display "ErC" if there is
EEPROM data reading error or the
calibrating process is not finished. Please
contact your supplier.
Low-voltage signal when the battery voltage
is below2.61V±2%. Please replace battery.
Power Off Mode
The thermometer will power off automatically if no activity is detected for 5
seconds.
Attention:
●Electromagnetic interference: INV-DC200 thermometer contains
sensitive electronic components. You should not use the thermometer in
an area with electromagnetic interference (e.g. near mobile phones or
microwaves)
●Please dispose the used thermometer and batteries in accordance with
local regulation requirements.
●Please remove the battery if you will not be using the thermometer for
an extended period of time.
3 short ticks
and green
backlit for 3
seconds.
3 short ticks
and green
backlit for 3
seconds.
None
11
hygiene.
 Make sure that both user and thermometer have stayed in
steady-state room condition for at least 30 minutes. Recent exposure
to hot or cold temperatures will impact your reading.
 If taking multiple readings, it is advised to wait at least 10 seconds
between readings. The thermometer is very sensitive to small
changes in temperature. Repeated use with no pause may impact
your reading.
 Before taking forehead measurement, remove hair, sweat, debris/oil.
 Before taking eardrum measurement, make sure ear canal is free from
obstructions or excess earwax build-up.
 As with any thermometer, proper technique is critical to
obtaining accurate measurements. Failure to follow instructions
will result in inaccurate measurements.
 Normal body temperature is a range and varies by site. Therefore,
measurements from forehead and eardrum should not be directly
compared.
 In general, an ear temperature is
than an oral temperature, whereas a forehead temperature is usually
0.5-1°F (0.3-0.6°C) lower than an oral temperature. Therefore, it is
NORMAL to get 1-2°F (0.6-1.2°C) difference between an ear
measurement versus a forehead measurement. This is NOT due to
the inaccuracy of the thermometer.
●Battery Installation:
1. Slide the battery cover off along the marked direction.
2. Put two AAA batteries into the battery compartment according to the
stated polarities.
3. Slide the battery cover horizontally until it snaps back in place.
Notes:
☆ Prior to using the thermometer for the first time, pull the plastic tab off
the battery.
usually 0.5-1°F (0.3-0.6°C) higher
4

Hide quick links:

Advertisement

loading