Installation Instructions - Hotsy 555SS Operating Instructions And Parts Manual

Electric powered direct drive hot water pressure washer
Table of Contents

Advertisement

INSTALLATION & OPERATION INSTRUCTIONS
Crossfi re Oil Burner
Burner Air Adjustment: The oil burner on this machine
is preset for operation at altitudes below 500 feet. If
operated at higher altitudes, it may be necessary to
adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.
Burner Air Adjustment
Reference Numbers
Air Band
Air Band Locking Screws
CAUTION: If white smoke appears from burner ex-
haust vent during start-up or operation, discontinue
use and readjust air bands.
NOTE: If a fl ue is installed, have a professional service-
man adjust your burner for a #1 or #2 smoke spot on
the Bacharach scale.
8
HOTSY 555SS • 8.914-354.0 • Rev. 01/16

Advertisement

Table of Contents
loading