Installation Instructions; Getting Started; Location; Electrical - Hotsy 1800 Series Operator's Manual

Stationary pressure washer
Hide thumbs Also See for 1800 Series:
Table of Contents

Advertisement

Operations

Installation Instructions

Getting Started

IMPORTANT: Proper initial installation of
equipment will assure more satisfactory perfor-
mance, longer service life, and lower maintenance
cost.
IMPORTANT: The use of a back flow preventer on
the water supply hose is recommended and may be
required by local code.

Location

The location should protect machine from damaging
environmental conditions, such as wind, rain and
freezing.
1. The machine should be run on a level surface where
it is not readily influenced by outside sources such
as strong winds, freezing temperatures, rain, etc.
The machine should be located considering accessi-
bility for the replacing of components and the refilling
of detergents, adjustments and maintenance.
Normal precautions should be taken by the operator
of the machine to prevent excess moisture from
reaching the machine.
2. It is recommended that a partition be made between
the wash area and machine to prevent direct spray
from the spray gun from coming in contact with the
machine. Excess moisture reaching the power unit
or electrical controls will reduce the machine's life
and may cause electrical shorts.
3. During installation of the machine, beware of poorly
ventilated locations or areas where exhaust fans
may cause an insufficient supply of oxygen. Suffi-
cient combustion can only be obtained when there is
a sufficient supply of oxygen available for the
amount of fuel being burned. If it is necessary to
install a machine in a poorly ventilated area, outside
fresh air may have to be piped to the burner and a
fan installed to bring the air into the area.
4. Do not locate near any combustible material. Keep
all flammable material at least 20 feet away. Electric
products incorporate parts that produce sparks and
therefore when located in a garage, it should be in a
room or enclosure provided for the purpose, or
should be 18"(45cm) or more above the floor. Install
on non combustible flooring and have a 36" (90cm)
minimum working clearance.
Local code will require certain distances from floor
and walls.
WARNING: Avoid small areas or near exhaust fans.
AVERTISSEMENT: Éviter les petites superficies ou
les surfaces à proximité des ventilateurs d'extraction
14
MANUAL, OPERATOR, HOTSY, STAT ELEC NG-LP

Electrical

WARNING: Make sure all switches and controls are
in the OFF position prior to connecting electrical
supply.
AVERTISSEMENT: S'assurer que tous les
commutateurs et tous les contrôles se trouvent en
position d'arrêt avant de raccorder l'alimentation
électrique.
WARNING: DO NOT stand in water while
connecting and disconnecting electrical supply.
AVERTISSEMENT: NE PAS se tenir debout dans
l'eau au moment de brancher ou de débrancher
l'alimentation électrique.
CAUTION: Hazard of electric shock - More than one
disconnect switch is required to disconnect all
power.
ATTENTION: Risque de choc électrique. - Plus d'un
sectionneur est requis pour débrancher toutes les
sources d'alimentation.
CAUTION: Use copper conductors only.
ATTENTION: Utiliser des conducteurs en cuivre
seulement.
IMPORTANT: Consult local building codes for exact
electrical requirements. Licensed contractors may
be required.
9.808-037.0-A