Venting
CAUTION: All venting must be in accordance with ap-
plicable federal and state laws, and local ordinances.
Consult local heating contractors.
If the pressure washer is to be used in an enclosed area,
a flue must be installed to vent burner exhaust to the
outside atmosphere. Be sure the flue is the same size
as the burner exhaust vent on the pressure washer lid.
Poor draft will cause the pressure washer to soot and
not operate properly. When selecting the location for
installation, beware of poorly ventilated locations or areas
where exhaust fans may cause an insufficient supply of
oxygen. Proper combustion can only be obtained when
there is a sufficient supply of oxygen available for the
amount of fuel being burned. If it is necessary to install
the machine in a poorly ventilated area, outside fresh air
may have to be piped to the burner and a fan installed to
bring sufficient air into the machine. Locate the pressure
washer so that the flue will be as straight as possible and
protrude through the roof at a proper height and location
to provide adequate draft. This oil fired pressure washer
must have a draft regulator installed in the flue (available
from most heating contractors). A draft regulator will permit
proper upward flow of exhaust flue gases.
Burner Air Adjustment: The oil burner on this machine is
preset for operation at altitudes below 500 feet. If operated
at higher altitudes, it may be necessary to adjust the air
band for a #1 or #2 smoke spot on the Bacharach scale.
To adjust, start machine and turn burner ON. Loosen two
locking screws found on the air band and close air band
until black smoke appears from burner exhaust vent. Note
air band position. Next, slowly open the air band until white
smoke just starts to appear. Turn air band halfway back
to the previously noted position. Tighten locking screws.
For higher altitudes, the air band opening may need to
be increased; for lower altitude, the .air band may need
to be decreased.
For higher humidity, the air band opening may need to be
increased; for lower relative humidity, the .air band may
need to be decreased.
For higher ambient temperatures the air band opening may
need to be increased; for lower ambient temperatures, the
air band opening may need to be decreased.
Adjust to your operating location's environment as-needed
for best smoke spot and performance compliant with local,
state, and federal regulations.

INSTALLATION INSTRUCTIONS

HOTSY 680SS • 8.914-368.0
Crossfire Oil Burner
Burner Air Adjustment: The oil burner on this machine
is preset for operation at altitudes below 1000 feet. If
operated at higher altitudes, it may be necessary to
adjust the air band for a #1 or #2 smoke spot on the
Bacharach scale.
To adjust, start machine and turn burner ON. Loosen
two locking screws found on the air band and close air
band until black smoke appears from burner exhaust
vent. Note air band position. Next, slowly open the air
band until white smoke just starts to appear. Turn air
band halfway back to the previously noted position.
Tighten locking screws.