IMPORTANT: Proper initial installation of
equipment will assure more satisfactory perfor-
mance, longer service life, and lower maintenance
cost.
IMPORTANT: The use of a back flow preventer on
the water supply hose is recommended and may be
required by local code.
The pressure washer should be run on a level surface
and in a protected area where it is not readily influ-
enced by outside forces such as strong winds, freezing
temperatures, rain, etc. The pressure washer should be
located to assure easy access for filling of fluids, adjust-
ments and maintenance. Normal precautions should be
taken by the operator to prevent moisture from
reaching the pressure washer. It is recommended that
a partition be made between the wash area and the
pressure washer to prevent direct spray from the wand
from coming in contact with the pressure washer.
Moisture reaching the equipment will reduce the
pressure washer's service life. All installations must
comply with the local codes covering such installations.

Electrical

WARNING: Make sure all switches and controls are
in the OFF position prior to connecting electrical
supply.
AVERTISSEMENT: S'assurer que tous les
commutateurs et tous les contrôles se trouvent en
position d'arrêt avant de raccorder l'alimentation
électrique.
WARNING: DO NOT stand in water while
connecting and disconnecting electrical supply.
AVERTISSEMENT: NE PAS se tenir debout dans
l'eau au moment de brancher ou de débrancher
l'alimentation électrique.
CAUTION: Hazard of electric shock - More than one
disconnect switch is required to disconnect all
power.
ATTENTION: Risque de choc électrique. - Plus d'un
sectionneur est requis pour débrancher toutes les
sources d'alimentation.
12
MANUAL, OPERATOR, HOTSY, STAT ELECTRIC, OIL
CAUTION: Use copper conductors only.
ATTENTION: Utiliser des conducteurs en cuivre
seulement.
IMPORTANT: Consult local building codes for exact
electrical requirements. Licensed contractors may
be required.
This machine is designed for connection to an overload
protected grounded circuit. It is recommended this
circuit be protected by a UL approved ground fault
circuit interrupter (GFCI). An electrical disconnect must
be provided in this circuit. All wiring must be of proper
voltage and amperage rating and conform to applicable
codes. A hole has been provided in the control box for
attachment of 1 inch electrical conduit.
For proper operation the motor rotation is to be counter-
clockwise as viewed looking towards the rear of the
motor (opposite pump attachment). If the rotation is
incorrect, interchange any two of the power supply
connections to reverse rotation.

Venting

DANGER: DO NOT run machine indoors or in an
enclosed area without proper ventilation, as
exhaust fumes may be hazardous to your health.
DANGER: DO NOT operate machine in areas where
flammable vapors (gasoline, solvents, etc.) may be
present, as this machine may ignite the vapors.
CAUTION: All venting must be in accordance with
applicable federal and state laws, and local ordi-
nances. This machine is not to be connected to a
type B gas vent. Consult local heating contractors.
Power In