Installation

Section 3
Installation
3.1 Installing UV System
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle.
Prerequisites:
Determine appropriate indoor location of the controller and chamber, refer to
Make sure that the controller is installed higher than the chamber and away from all water sources.
Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.
Make sure to turn off the main water supply.
Make all necessary plumbing connections refer to
Procedure:
1
• Install the UV Chamber
vertically with the following
spacing on the wall using
screws.
• PRO10: 18.5"
• H, PRO20: 27.5"
• K, PRO30/50: 37.5"
Note: Ensure chamber is
installed with green arrows
pointing upwards.
5
• Insert sleeve with arrow
pointing up.
Note: DO NOT rotate sleeve
and touch glass with bare
hands.
8
C A U T I O N
Section
2 2
• Connect Flow Meter Sensor
(PRO10,20,30 models only)
to chamber using 1¼" unions
supplied.
Note: LED must face up.
Ensure proper length of
straight pipe 1.0" Diameter at
inlet side of Flow Meter
Sensor and use a 1¼" to 1"
Reducing Coupler (not
supplied).
6
• Wet O-ring with water then
place over top end of sleeve.
Section
2.1.
3
• Install the sensor to the UV
system (for PRO models
only).
Note: DO NOT use wrench to
tighten the sensor.
7
2
1
• Connect the sleeve bolt to the
top of the sleeve assembly.
Ensure sleeve bolt is rotated
full 1/4 turn until positive stop.
2.1.
4
2
1
• Connect the sleeve bolt at the
bottom of the sleeve
assembly. Ensure sleeve bolt
is rotated full 1/4 turn until
positive stop.
8
2
1
• Remove the sleeve bolt at the
bottom of the sleeve
assembly.