Technical Specifications; Power Data; Electronics/General Data - WEG CFW100 User Manual

Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

Available languages

Available languages

8 TECHNICAL SPECIFICATIONS

8.1 POWER DATA

Power Supply:
Tolerance: -15 % to +10 %.
Frequency: 50/60 Hz (48 Hz to 62 Hz)
Phase imbalance: ≤ 3 % of the rated phase-to-phase input voltage.
Overvoltage according to Category III (EM 61010/UL 508C).
Transient voltages according to Category III.
Maximum of 10 connections per hour (1 every 6 minutes).
Typical efficiency: ≥ 97 %.
For further information about the technical specifications, refer to

8.2 ELECTRONICS/GENERAL DATA

CONTROL
METHOD
OUTPUT FREQUENCY
PERFORMANCE V/f CONTROL
VECTOR CONTROL
(V V W )
INPUTS
DIGITAL
SAFETY
PROTECTION
Table 8.1: Electronics/General Data
Types of control:
- V/f (Scalar);
- V V W: voltage vector control.
PWM SVM (Space Vector Modulation)
0 to 300 Hz, resolution of 0.1 Hz.
Speed regulation: 1 % of the rated speed (with slip
compensation).
Speed variation range: 1:20.
Speed regulation: 1 % of the rated speed.
Speed variation range: 1:30.
4 isolated inputs.
Maximum input voltage of 30 Vdc.
Input current: - 11mA.
Maximum input current: -20mA.
Output overcurrent/short-circuit.
Under/overvoltage.
Motor overload.
Overtemperature in the power module (IGBTs).
Fault / external alarm.
Programming error.
Technical Specifications
annex
B.
CFW100 | 37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents