Description Ofiec 61010 Measurement Categories - Tektronix DMM4040 Safety And Installation Instructions Manual

Hide thumbs Also See for DMM4040:
Table of Contents

Advertisement

I
DMM4040 and 4050
Safety and Installation Instructions
Description of IEC 61010 Measurement Categories
The lEC 61010 safety standard
defines
four Overvoltage (Insta llation) Categories (CAT I
to CAT IV) based on the magnitude of danger from transient impulses as shown in Figure
1.
CAT I
Electronic
CAT II
CAT III
Appliances,
I
MC Panels,
etc
.
PCs, TVs
Service
Enlrance
Service
Enlra
nce
CAT IV
- - - - - - 1
Meier
Underground Service
I
OUlbuilding
Transformer
Oulbuilding
Meier
Underground Service
I
caUtJwhs.c
ps
Figure 1. IEC 61010 Measurement Category (CAT) Levels
The lEC 61010 Measurement CAT level indicates the level of protection the instrument
provides against impulse withstand
voltage.
CAT I equipment is designed to protect against transients from high-voltage, low-energy
sources, such as electronic
circuits
or a copy
machine.
CAT II equipment is designed to protect against transients from energy-consuming
equipment supplied from the fixed
installation,
such as TVs,
PCs,
portable tools, and
other household
appliances.
CAT III equipment is designed to protect against transients in equipment in fixed
equipment
installations,
such as distribution panels, feeders and short branch circuits, and
lighting systems in large
buildings.
CAT IV equipment is designed to protect against transients from the primary supply
level, such as an electricity meter or an overhead or underground utility