UPLOADING/DOWNLOADING

As previously described (page 16), the i750TC can be paired using the Bluetooth® feature. This requires a PC,
Mac, or mobile device running Diverlog software and equipped with Bluetooth® functionality. If your personal com-
puter is not equipped with internal Bluetooth® hardware, a Bluetooth® dongle can be purchased separately from
a computer store.
Alternately, The i750TC is configured with a 4 pad data connection port located on the back of the case. It can
be used with the included adapter clip to connect the i750TC with a PC or Mac using a USB cable. Connect the
adapter clip to the i750TC. When connecting the adapter clip to the i750TC, ensure that the 4 pins on the clip
are properly fitted over the 4 pads on the i750TC. Then connect the USB interface cable to the adapter clip. The
i750TC and USB cable assembly can now be connected to a PC or Mac running Diverlog software.
NOTE: If a USB cable is connected to the i750TC, Bluetooth® connection will be blocked or disabled.
Though any active downloads, uploads, or firmware updates using Bluetooth® will be allowed to finish
first.
DATA PORT
4 pads

CARE AND CLEANING

Protect your i750TC from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens
against scratches with the stick on i750TC lens protector. Small scratches will naturally disappear underwater.
• Soak and rinse the i750TC in fresh water at the end of each day of diving, and check to ensure that the areas
around the low pressure (depth) sensor, PC interface data port, and buttons are free of debris or obstructions.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After
removal from the bath, place the i750TC under gently running fresh water. Towel dry before storing.
• Keep your i750TC cool, dry, and protected during transport.
low pressure
sensor

SERVICE

WARNING: At a minimum, annually check the altitude reading on the ALT 2 screen (p. 27) and Pre-
!
Dive Planner (p. 28, 73) for accuracy. If your i750TC is ever out of calibration (incorrect elevation reading,
incorrect No Decompression Dive Times in the planner, or showing a depth reading at the surface) or
displays an error code message, it must be serviced at the factory before use.
If required to return your i750TC to Aqua Lung:
• Obtain an RA (Return Authorization) number by contacting http://www.aqualung.com/us/support/contact-us or
(760) 597-5000
• Record all dive data in the Log and/or download the data stored in memory. All data will be erased during factory
service.