Ss (Safety Stop); Low Battery While On The Surface - Aqua Lung i750TC Owner's Manual

Table of Contents

Advertisement

• While 3 m (10 ft) deeper than the calculated Deep Stop, you will be able to access a Deep Stop Preview screen
that will display the current calculated Deep Stop Depth/Time.
• Upon initial ascent to within 3 m (10 ft) below the calculated Stop Depth, a Deep Stop screen displaying a Stop
Depth at ½ the Max Depth will appear with a countdown timer beginning at 2 min and counting down to 0. If you
descend 3 m (10 ft) below, or ascend 3 m (10 ft) above, the calculated Stop Depth for 10 seconds during the
countdown, the No Decompression Main will replace the Deep Stop Main display and the Deep Stop feature will
be disabled for the remainder of that dive. There is no penalty if the Deep Stop is ignored.
• In the event that you enter Decompression, exceed 190 ft (57 m), or a High O2 SAT (Oxygen Saturation) condi-
tion, ≥ 80%, occurs, the Deep Stop will be disabled for the remainder of that dive.
• The Deep Stop is disabled during a High PO

SS (SAFETY STOP)

Upon ascent to within 1.5 m (5 ft) deeper than the Safety Stop depth set for 1 second on a No Decompression
dive in which depth exceeded 9 m (30 ft) for 1 second, a beep will sound and a Safety Stop at the depth set will
appear on the Dive Main display with a countdown beginning at the Safety Stop time set and counting down to
0:00.
• If the Safety Stop was set for OFF, the display will not appear.
• In the event that you descend 3 m (10 ft) deeper than the Stop Depth for 10 seconds during the countdown,
or the countdown reaches 0:00, the No Decompression Main screen will replace the Safety Stop Main screen
which will reappear upon ascent to within 1.5 m (5 ft) deeper than the Safety Stop depth set for 1 second.
• In the event that you enter Decompression during the dive, complete the Decompression obligation, then de-
scend below 9 m (30 ft); the Safety Stop Main will appear again upon ascent to within 1.5 m (5 ft) deeper than
the Safety Stop depth set for 1 second.
• If you ascend to 0.9 m (3 ft) of the surface for 1 second, the Safety Stop will be canceled for the remainder of
that dive.
• There is no penalty if you surface prior to completing the Safety Stop or choose to ignore it.

LOW BATTERY WHILE ON THE SURFACE

Warning Level
• The i750TC functions continue but but screen brightness is limited to 60% max.
• The Battery icon appears amber.
© Aqua Lung International, Inc. (2016)
Alarm condition, ≥ set point.
2
21
DIVE FEATURES
Doc. 12-7852-r05 (8/5/16)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents