UPLOADING/DOWNLOADING DATA

As previously described (page 28), the i550C can be paired using the Bluetooth® feature. This requires a mobile
device with Bluetooth® running Diverlog+ software.
The Settings Upload portion of the program can be used to set/change the Gases, Set AL group (Alarms), Set
UTIL group (Utilities), and Set TIME group (Time/Date) using the same Interface System. The Mode settings must
be entered using the i550C button controls.
Information available for retrieval (download) from the i550C includes items such as dive number, surface interval
time, depth, dive time, start dates/time, lowest temperature, sampling rate, set points, N2 Bar Graph, and ASC Bar
Graph.
Refer to the Diverlog+ software application for further instruction on linking your i550C to your mobile device.
water
contacts
depth
sensor

CARE AND CLEANING

Protect your i550C from shock, excessive temperatures, exposure to chemicals, and tampering. Protect the lens
against scratches with an Instrument Lens Protector. Small scratches will naturally disappear underwater.
• Soak and rinse the i550C in fresh water at the end of each day of diving, and check to ensure that the areas
around the Low Pressure (Depth) Sensor, water contacts, and buttons are free of debris or obstructions.
• To dissolve salt crystals, use lukewarm water or a slightly acidic bath (50% white vinegar/50% fresh water). After
removal from the bath, place the i550C under gently running fresh water. Towel dry before storing.
• Keep your i550C cool, dry, and protected during transport.

SERVICE

WARNING: At a minimum, annually check the altitude reading on the ALT 2 screen (p. 19) and Pre-Dive
!
Planner (p. 20, 54) for accuracy. If your i550C is ever out of calibration (incorrect elevation reading, incor-
rect No Decompression Dive Times in the planner, or showing a depth reading at the surface) or displays
an error code message (EEP, ALT, CAL, ERR, CSM, A-D), it must be serviced at the factory before use.
If required to return your i550C to Aqua
• Obtain an RA (Return Authorization) number by contacting http://www.aqualung.com/us/support/contact-us or
(760) 597-5000
• Record all dive data in the Log and/or download the data stored in memory. All data will be erased during factory
service.
• Package it using a protective cushioning material.
• Include a legible note stating the specific reason for return, your name, address, daytime phone number, serial
number(s), and a copy of your original sales receipt and Warranty Registration.
• Send freight prepaid and insured using a traceable method.
• Non-warranty service must be prepaid. COD is not accepted.
• Additional information is available on the Aqua Lung web site www.AquaLung.com or on the local Aqua Lung
web site that serves your global region.
© Aqua Lung International, Inc. (2018)