CAN BE USED AS
• Dive Computer (Air or Nitrox)
• Digital Depth Gauge/Timer
• Free Dive Computer
DIVE COMPUTER PERFORMANCE
• Bühlmann ZHL-16C based Z+ algorithm
• Decompression in agreement with Bühlmann ZHL-16C
• No Decompression Deep Stops - Morroni, Bennett
• Decompression Deep Stops (not recommended) - Blatteau, Gerth, Gutvik
• Altitude - Bühlmann, IANTD, RDP (Cross)
• Altitude corrections and O2 limits based on NOAA tables
OPERATIONAL PERFORMANCE
Function:
Accuracy:
• Depth
±1% of full scale
• Timers
1 second per day
Dive Counter:
• DIVE/GAUGE displays Dives #1 to 24, FREE displays #1 to 99 (0 if no dive made)
• Resets to Dive #1, upon diving (after 24 hours with no dives)
Dive Log Mode:
• Stores 99 most recent DIVE/GAUGE dives in memory for viewing
• After 99 dives, adds 100th dive in memory and deletes the oldest dive
Altitude:
• Operational from sea level to 14,000 feet (4,270 meters) elevation
• Measures ambient pressure every 30 minutes when inactive, upon activation, every 15 minutes while activated.
• Does not measure ambient pressure when wet.
• Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet
(305 meters) higher.
Power:
• User replacement battery.
• (1) 3 vdc, CR2, 800 mAh, Lithium battery (Duracell, Energizer, Panasonic, or Rayovac recommended) 15 oper-
ating hours at 100% brightness with Auto Dim set off.
• Shelf life Up to 5 years (dependent on battery manufacturer)
Power Saver Mode (surface):
• Activates and turns screen off when 2 minutes elapse on surface with no button operations.
• Resume operation from Power Saver Mode by pressing any button.
Battery Indication:
• Green (Good) - Green Icon displays on the Suface Main. No battery icon during the dive.
• Amber (Warning) - Amber Icon solid on the Surface and Dive Main screens. Battery change is recommended.
Brightness level will automatically be limited to 60% maximum.
• Red (Alarm) - Red Icon flashing on the Surface and Dive Main screens. If during a dive, the message GO UP
LOW BATTERY flashes. If on the surface, the message CHANGE BATT flashes until the unit shuts off. The bat-
tery must be changed before using your i750TC
Operating Temperature:
• Out of the water - between -6.6 and 60 °C (20 °F and 140 °F).
• In the water - between -2.2 and 35 °C (28 °F and 95 °F).