Scientific Atlanta D9225 Installation And Operation Manual page 47

Advertisement

...$ERXWRWKHU6HDUFK6HWXSRSWLRQV
Signal searches are constrained or limited by the current Search Type and the
boundary settings for the Lower and Upper Range. When searching for a signal,
the receiver uses the Search Type as the primary search criteria. For example, if the
FEC Rate is set as the Search Type, only signals that match the current FEC Rate
(set at the Receiver Setup menu) within the current Lower/Upper Range frequency
boundaries are examined for a possible match. Signals associated with all other
FEC Rates are ignored (see also "...About I/Q signal inversion").
To set the Search Mode…
Step 1.
Search Mode
Step 2.
Step 3.
Available options: Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Setting the Search Mode to ON enables the signal search for automatic activation.
You can disable the signal search option by setting the Search Mode to OFF.
To set the Search Type…
Step 1.
Search Type
Step 2.
Step 3.
Available options: Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Table9. Available Search Type options
Option
Description
Repeat the above action to change the Search Type. If you are unsure about which
Search Type to use for best results, contact your dealer/reseller, or local service
provider.
To set the Lower and Upper frequency ranges for the search…
Step 1.
Lower Range
Ï Ð
Step 2.
Upper Range
Ï Ð
Step 3.
Step 4.
Available options: Press 1 to save the new settings (Yes), or press 2 to discard all
changes (No), or press 3 to cancel the operation (Cancel).
Repeat this action to change to another frequency. If you are unsure about which
frequencies to use, contact your dealer/reseller, or local service provider.
 