Service And Cleaning - Effecta Pellets 222 Owner's Manual

Table of Contents

Advertisement

Service and cleaning

Cut the power to the boiler before starting the service. We recommend a good service/
cleaning of the burner and boiler 2-3 times a year. Do as follows for best result and
minimizing the chances for downtime.
Sweeping range
1. Ash compartment, after about 3 tons of pellet consumption
2. Burner, according to the manufacturer´s instructions
3. Convection part, after about 3 tons of pellet consumption
3. Without automatic cleaning every other week in winter
4. Ashbox when necessary
5. Sootbox after about 3 tons of pellet consumption
6. Flue tube after about 3 tons of pellet consumption
Cleaning the ash compartment
Cleaning the ash compartment is done through the ash door on the front. The easiest way is to
use some type of ash cleaner. If you do not have access to a an ash cleaner, remove the ash
with a scrape and keep it in a fireproof bin. Remember that ashes can contain hot particles for
a long time and may not be stored near flammable materials.
Cleaning the burner
Clean the burner according to the manufacturer´s instructions. If you have an Effecta Supra
read more about service and cleaning in the burner manual.
Cleaning of the convection part
Clean the tubes with the supplied brush, follow instructions how to remove the turbulators on
pg 13. It´s important for the boilers efficiency that these are cleaned thoroughly at the service.
Cleaning of sootbox and fluetube
Soot box, which is placed above the tubes must be emptied of ash, if the soot box is full, the
flue gas has no place to escape out through the chimney and you will receive a disruption. Also
clean the flue tube that goes to the chimney, when it is not certain that the chimney sweep do it.
1 0
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents