Trouble Shooting - Effecta Pellets 222 Owner's Manual

Table of Contents

Advertisement

Trouble shooting

There are actions that the end user can take to fix a disruption. However, a professional should
always be contacted before any adjustment is done.
Fault
Low room temperature
Burner "puffs" at start
The panel is "black"
Overheating protection on the
burner activated
Ash is black, not grey/white
Poor hot water capacity
Soot in the boiler room
High flue gas temperature
White smoke from the chimney
The burner doesn´t start
2 0
Effecta AB - Västra Rågdalsvägen 21 - 434 99 Kungsbacka - +46(0)300 - 22320 - info@effecta.se
Cause
- Incorrect set on shunt valve
- Radiator pump not activated
- Air in radiators
- Low boiler temp.
- Incorrect start dose
- Overheating protection has tripped
- Low draft
- Burner filled with ash
- Poor combustion
- Low boiler temp
- Ti high flow in the pipes/system
- Leaking seals
- Sooty boiler
- Poor combustion
- Broken sensor
- Low flue gas temperature
- To big chimney
- Rainwater in the chimney
- Micro switch broken
- Overheating protection activated
- No fuel
Action
- Adjust
- Activate
- Vent the system
- Check burner/electrical heater
- Adjust start dose
- Reset (pg 7)
- Check draft
- Clean burner
- Contact installer
- Set the burners stop-temp higher
- Adjust the flow on the mixing valve
- Check seals, contact installer
- Clean boiler
- Contact installer
- Contact installer
- Cut turbulators/increase power
- Contact installer
- Mount a rain hood
- Check switch
- Reset protection
- Fill up with fuel

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents