Recording (Transient) - Ametek TR-2100 Operation Manual

Multi - function recorder
Table of Contents

Advertisement

TR-2100 User Manual

Recording (Transient)

Recording resolution
Dynamic range
Recording accuracy
Sample rate
Pre-fault time
Post-fault time
Safety window
Maximum record length
Synchronization
Programmable Features
Configuration Switches
16 bits (65536 levels)
96.3 dB
+/- 1 LSB
Up to 19,200 per sec. at 50 Hz
Up to 23,040 per sec. at 60 Hz
COMTRADE rates supported
Analogues and digitals can have different rates
2 - 500 cycles
Fault length will extend as long as a trigger condition
exists
Minimum is 8 - 100 cycles
Recording time after trigger: 4 - 16 cycles
1 - 30 sec. (This prevents memory filling with a
continuous trigger)
All analogue channels sampled together and time
tagged to better than +/- 100 ns (if GPS option is used)
Sample rates
Pre, max & min post fault times
Safety window
Maximum record length
Trigger level and polarity
Trigger enable
Time and date
Channel labels
Local time offset
Number of analogue channels
Number of digital channels
System frequency (50/60)
Printer connected
Modem connected
Network connected
Cross trigger enabled
64

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents