7. Locate the correct jumper and move it ON or OFF as needed to set up the
channel correctly.
Figure 15 Analogue Input Board Jumpers
Jumper References
For Voltage input (212.12 V AC RMS) jumper is fitted in position JP0.
For Current input (1.414 V AC RMS) jumper is not fitted.
For the special input (12 V DC) the jumper is fitted in position JP1.
Position JP2 is unused.
8. Now that the channel is set up as needed for Voltage, Current, or Special
input, change any other channels/cards as needed at this time also.
9. Once all jumpers are set correctly, make sure all the boards are properly
reseated. Next, the two white brackets should be reinstalled, followed by
the gray ribbon cables and power cables. The orange input plugs can now
be inserted back into the rear of the input cards.
10. Turn the internal power switch to the ON position, and close the front cover
of the unit.
11. Wait at least two (2) minutes for the unit to power up. Once the POWER,
ON LINE, and ATTENTION LED's are on, the unit has powered up and
you can continue.