Digital Input Resistor Table
If necessary, the Digital Inputs can be changed to accept a different voltage level. For the
Analogue Input boards the digital inputs use Resistors R9000 – R9015. For the Digital-only
Input boards the digital inputs use resistors R1 – R32. Reference the Input Module
schematics for resistor locations and change the value to match the Digital input voltage.
Table 12
Input VDC
(Nominal)
12V
24V
48V
125V
250V
Analogue Input Board Jumper Locations
Set the Input Board configuration jumpers per Table 13. Refer to Figure 12 for the location
of each configuration jumper.
Table 13
Board No. Analogue Channels
1
2
3
4
Input Board Analogue Input Range Selection Table
Set the Analogue Input Board range selection jumpers per Table 14. Refer to Figure 12 for
the location of each range selection jumper.
Table 14
Input Range
0-2 Vpk (Current)
0-300 Vpk (Voltage)
0-12 Vpk
TBD
Resistor
3.6K
Carbon Composition
Resistor (1W)
6.8K
Carbon Composition
Resistor (1W)
15K
Carbon Composition
Resistor (1W)
39K
Carbon Composition
Resistor (1W)
82K
Carbon Composition
Resistor (2W)
BRD SEL 0
1-8
On
9-16
Off
17-24
On
18-32
Off
Jumper
None
JP0
JP1
JP2
Description
Ametek Part No.
BRD SEL 1
On
On
Off
Off
Resistor Selected
Rx06 (909 Ohm)
Rx07 (26.7 KOhm)
Rx08 (TBD)
47
4716-130
4716-140
4716-152
4716-164
4716-180
None