3

Technical Data

Dimensions:
Operating voltage:
Power consumption:
Max. torque:
Opening angle:
Time delay:
Opening speed:
Closing speed:
Noise emission
Environment condi-
tions
Temperature range:
Humidity range:

3.1 Permissible door leaf weights and door widths

The curves are calculated using the following formula:
Standard arms
Slide arms
Page 4 of 55
Operator 600 x 85 x 124 mm (w x h x d)
230V∼
Standby 13 W, rated power 67 W
50 Nm
adjustable from 70° to 115°
adjustable from 0 to 20 seconds
adjustable from 3 to 20 seconds
adjustable from 5 to 20 seconds
-18 dB
-15 to + 50°C
up to 85% relative humidity, non condensing
J = 1/3 × m × b
2
: J max. 65 kgm
2
: J max. 65 kgm
12/2006 Rev. B
2
Key : J = mass moment of inertia [
m = door leaf weight [kg]
b = door leaf width [m]
2
]
kgm
Manual DFA 127 Full Power