Record DFA 127 User Manual page 32

Automatic swing door operator
Hide thumbs Also See for DFA 127:
Table of Contents

Advertisement

Configuration
Parameter
MASTER/SLAVE
2 DOOR LEAVES
Function AKA
Overlap
Open sequence
Close sequence
Page 32 of 55
Setting
Factory
range
default
Master +
Master +
Slave
Slave
Master
only
0 - 40
5
0 - 40
5
0 - 40
20
12/2006 Rev. B
Description
AKA is effective on both operators
Entry AKA is only effective on the
Master operator, AKI and SSK are
effective on both operators. One-way
mode not possible.
Only one door leaf moves in the pre-
set overlap region.
During the opening, the stationary
leaf waits until the moving leaf has
left the overlap region y.
During closing, the moving leaf waits
until the stationary leaf has closed.
Delayed start-up of the stationary
leaf
Delayed closing of the moving leaf
All modulators at 0 = synchronous
activity.
Opening or closing sequence on 40:
The subsequent door leaf waits until
the first leaf has entirely opened or
closed. With this setting, the overlap
has the highest priority.
Manual DFA 127 Full Power

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents