4

Specifications

4
Specifications
4.1

Tecnical data

Dimensions (W x H x D)
Operating voltage:
Power consumption:
Max. torque:
Max. Mass inertia of door leaf:
Opening angle:
Hold-open time
Opening speed:
Closing speed:
Noise level:
Protection class:
Temperature range:
Humidity range:
4.2

Door leaf weights and door widths

600
500
400
300
200
100
0
0.6
Recommended door leaf width for door closer size according to
The curve is calculated using the following formula:
Standard arm:
Sliding arm:
18 / 34
900 x 70 x 127 mm
110 – 240 VAC, 50/60 Hz
Standby 13 W, Nominal power 67 W
50 Nm
65 kgm
Adjustable from 70° to 115°
Adjustable from 0 to 60 seconds (40 steps)
Adjustable from 3 to 20 seconds (40 steps)
Adjustable from 5 to 20 seconds (40 steps)
< 45 dB
IP20
From -15 to +50° C
Up to 85% rel. humidity, not condensing
0.7
0.8
0.9
Door leaf width (m)
2
J max. 65 kgm
2
J max. 65 kgm
2
1.0
1.1
EN 4
EN 5
2
J=1/3 x m x b
Key:
J = moment of inertia kgm
m = weight of door leaf in kg
b = door leaf width in m
BAL_DFA_70_EN_1V0_REC_102-127109270
1.2
1.3
1.4
EN 6
2

Advertisement