Configuration
Configurations of the DFA 127 can only be made with the electronic BDE-D or the
optional Testbox. If a toggle switch is connected, a BDE-D or Testbox must be con-
nected briefly for the configuration.
Please always leave the configuration review sheet in the drive even when the STG
is replaced!
15.2 Parameter Description
Parameter
DRIVING CYCLE
Closing speed
Opening speed
Acceleration
Latch check
TIME DELAY OPEN
Time delay open
Time delay SSK
DRIVE
Opening angle
Collision
Brake
Page 30 of 55
Setting
Factory
range
default
0 - 40
18
(5 – 20 s)
0 - 40
36
(3 - 20 s)
0 – 40
36
(40 = max.)
0 – 40
0
0 – 40
2
(0 – 60 s)
0 – 40
4
(0 – 60 s)
0 – 40
35
0 – 40
20
Without
Without
Closing
position
Opening
position
Open/clos
ed position
12/2006 Rev. B
Description
Slider control with 40 steps
Slider control with 40 steps
Influences the start-up behaviour
while opening and closing
Earlier slow-down while closing elon-
gates the length of run with minimal
possible closing speed in the area of
the last 20° (e.g. safeguarding
against shearing edge)
Effective with AKA, AKI and push to
actuate
0 – 20:
Steps of 1 s
21 – 40: Steps of 2 s
Effective with SSK
0 – 20:
Steps of 1 s
21 – 40: Steps of 2 s
The opening angle is estimated dur-
ing the calibration run and is equiva-
lent to the value of 40
Influences the force for the reversing
0:
weak
40:
strong
No brake integrated or no brake
wanted
Holding brake with closed door
Holding brake with open door
Holding brake with open and closed
door
Manual DFA 127 Full Power