Commissioning
12.6 Safety check
1. BDE position
2. Open door (e.g. with AKI)
3. Operate a safety device while closing. Door must re-open.
4. The same check must be performed with every safety device present.
12.7 Checking automatic reverse
1. Obstruct door while closing. The door must reverse. When the door next clo-
ses it moves at creep speed past the obstruction point.
2. Obstruct the door while opening. The door stops for hold-open time and clo-
ses. When the door next opens it moves at creep speed past the obstruction
point.
12.8
Touch control (push to actuate)
See about the configuration in chapter 15. By pressing lightly on the door, a
door-opening will be initiated.
12.9
Checking the functions of the DFA
• Check all the DFA functions
• Tighten the arm screw
12.10
Hand over to the client
• Instruct the client
• Hand over the operating manual
• RESET demonstration
Page 22 of 55
(automatic mode)
12/2006 Rev. B
Manual DFA 127 Full Power