1. Enter the detection distance for the plate poor contact sensor and press [ENT].
Do not change the value unless instructed to do so by a service
!
CAUTION
technician. Enter this value correctly. If an incorrect value is entered, plate
displacement will not be detected accurately during high-speed drum
rotation and this may result in damage to the PT-R.
2. When entry is complete, press [OK]. The plate ejecting direction selection
screen appears.

2.6 Selection of Plate Eject Direction

When you connect an AT-M type bridge, you can select the ejecting direction (or set
to external discharge) for each type of plate. There are three ejecting directions: left,
right, and straight.
When an AT-M type bridge is not connected the plate ejecting direction selection
NOTE
screen is not displayed.
When the AT-M type bridge is installed, it is set so that switching of the ejection
direction can only be done for the direction the online processor or the stocker is
connected.
If a direction is selected that the connected AT-M type bridge cannot switch to, an
error will occur when a plate is ejected.
• The direction of the arrow in the icon on the screen is the ejecting direction as
NOTE
seen from the front of the PT-R.
• Please select the ejecting direction for all registered media types that will be used.
1. Select the ejecting direction (or external discharge) and press [OK]. The laser
power and drum rpm setting screen appears.
5-14
Conveyor direction
ESC
OK
Fig. 5-12 Plate ejecting direction
selection screen
When left is selected
When straight is selected
When right is selected
When external discharge is selected