PT-R4300 USERS MANUAL

16. Canceling Calibration

On rare occasions the exposure quality may be worse after calibrating from the user
setting screen or by automatic calibration than it was before calibration. In this case,
cancel the effect of calibration and restore the laser to its previously calibrated state.
1. Select [Cancel calibration] in the user setting selection screen and then press
[OK]. The resolution selection screen appears.
2. Press the resolution button for which you want to cancel calibration and then
press [OK].
The calibration cancel selection screen appears.
The dates and calibration states of the last five calibrations are displayed. For
information on display of the calibration state, refer to "17. Calibration
Information".
Fig. 5-70 Calibration cancel selection screen
5-50
Resolution
1200
2000
2400
dpi
dpi
4000
2438
2540
dpi
dpi
ESC
OK
Fig. 5-69 Resolution selection screen
mm/dd hh:mm xxch xx% Exxx
1
2
mm/dd hh:mm xxch xx%
3
mm/dd hh:mm xxch xx% Exxx
4
5
ESC
OK
dpi
dpi