Version Change History Date Version Description Remark 2014/4/17 First release James.Chiu WMP-248/249 User’s manual...
Page 3
Intel is a trademark or registered trademark of Intel Corporation. Microsoft Windows is a registered trademark of Microsoft Corporation. Winbond is a registered trademark of Winbond Electronics Corporation. All other product names or trademarks are properties of their respective owners. WMP-248/249 User’s manual...
Page 4
To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Do not modify this equipment without authorization of the manufacturer. WMP-248/249 User’s manual...
Safety Instructions Intended use The WMP-248/249 is intended to serve as a medical monitor which is designed for general purpose for hospital environment and for diagnosis. It could be used for Surgical, Radiology, PACS (Picture Archiving Communication Systems), LIS (Lab Information Systems) and Electronic Medical Record purpose.
Page 6
If your hands are wet, do not touch the plug. Use your thumb and index finger, grip firmly on the power cord to disconnect from the electrical socket. By pulling the power cord, may result in damaging it. WMP-248/249 User’s manual...
Page 7
Unless proper ventilation is present, do not place unit in an enclosed area; such as a built-in shelf. Keep a minimum distance of 10 cm between the display unit and wall. WMP-248/249 User’s manual...
Page 8
(f) When the functions of the unit are dysfunctional. When replacement parts are needed for the medical panel PC unit, make sure service technicians use replacement parts specified by the manufacturer, or those with the same characteristics and performance as the original viii WMP-248/249 User’s manual...
Page 9
The mark on electrical and electronic products only applies to the current European Union Member States. WMP-248/249 User’s manual...
Page 10
IEC 60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certified equipment in the patient environment and IEC 60XXX certified equipment outside of the patient environment. If in doubt, consult the technical services department or your local representative. WMP-248/249 User’s manual...
C) Caution: This adapter SPI FSP180-AHAM1 is a forming part of the medical device Contact information: 3F, No.14, Prosperity Road II, Science-Based Industrial Park, Hsinchu, Taiwan 300, R.O.C TEL: (886) 3 5780000 E-Mail: Sales@wincomm.com.tw WMP-248/249 User’s manual...
Disconnect Device ............19 BIOS Setup ............20 Appendix .............. 30 A. Jumper settings and Connectors ..... 30 B. L type Stand (optional kit) ........ 53 C. Battery Pack Specifications (optional kit) ..54 D. Scrap Computer Recycling ........ 55 WMP-248/249 User’s manual...
Introduction Product Description The WMP-248/249 Medical Panel PC are based on Intel 4th generation Core i processor which can deliver faster graphic with higher CPU performance. It accommodates two SATA III devices and up to 16GB DDR3 SODIMM. The high brightness LCD, Low noise (WMP-248) / Fanless...
Before you begin installing your Medical Station, please make sure that the following items have been shipped: The WMP-248 or WMP-249 Medical Panel PC unit One DVD containing user manual, chipset drivers Power Adapter x 1 (Mf:SPI, type/model: FSP180-AHAM1) ...
Low noise Smart fan solution Anti-bacteria (MRSA) plastic housing Built-in Battery backup function (option) Supports PCI-E x 16 or PCI expansion slot (option) Support isolated module by different configuration (optional order configuration) WMP-248/249 User’s manual...
Reset x 1 DC-in Jack x 1(with lock function) Two 5W speaker on back side Isolation: 4KV isolated RS-232 x 1, RS-232/422/485 x 1 4KV isolated USB 2.0 x 1 (Full speed) 4KV isolated Lan x 1 (Gigabit) WMP-248/249 User’s manual...
Page 17
VESA 75/100mm Construction 3mm ABS + PC TYPE Plastic housing Dimension (WxHxD) 606 x 398 x 65.6 mm WMP-248: 8.5kg (w/o power adapter) Net Weight WMP-249: 9.0kg (w/o power adapter) Packing Filler Environmental Specifications Operating: 0°C to 40°C (32°F ~104°F) Temperature Storage, Transportation: -20°C to 60°C (-4°F...
Guidance and manufacturer’s declaration – electromagnetic emissions The model WMP-248/249 is intended for use in the electromagnetic environment specified below. The customer or the user of the model WMP-248/249 should assure that it is used in such an environment. Electromagnetic environment – Emissions test Compliance guidance WMP-248/249 User’s manual...
Page 19
The model WMP-248/249 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the model WMP-248/249 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment...
Guidance and manufacturer’s declaration – electromagnetic immunity The model WMP-248/249 is intended for use in the electromagnetic environment specified below. The customer or the user of the model WMP-248/249 should assure that it is used in such an environment. Immunity test IEC 60601 Compliance Electromagnetic environment –...
Guidance and manufacturer’s declaration – electromagnetic immunity The model WMP-248/249 is intended for use in the electromagnetic environment specified below. The customer or the user of the model WMP-248/249 should assure that it is used in such an environment. Immunity Electromagnetic environment –...
Page 22
If the measured field strength in the location in which the model WMP-248/249 is used exceeds the applicable RF compliance level above, the model WMP-248/249 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the model WMP-248/249.
Cleaning/Disinfecting Steps: 1. Wipe the WMP-248/249 with a dry clean cloth. 2. Prepare agent per manufacturer’s instructions or hospital protocol. Cautions: Do not immerse or rinse the WMP-248/249 and its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source.
USB-CD/DVD drive, turn on computer power, keep on pressing “F11” key, go into BIOS quick boot menu, select “USB-CD ROM”, WAIT FOR 20 SECONDS, then press enter, system OS will boot up from USB-CD/DVD drive directly. WMP-248/249 User’s manual...
1-2 Down. Battery1(Green) & Battery2(Yellow): LED 1 LED 2 (Charge/Discharge/Low) (Batt present/ not present) In charge blinking Discharge Full charge Low battery blinking blinking No battery 2. Power Button (with LED status indicator: ON: Green, OFF: dark) Operation: always on. WMP-248/249 User’s manual...
Page 28
10. Clean me (with LED status indicator: ON: Yellow, OFF: dark) a. Keep on contacting 5 seconds to active b. keep contacting 5 seconds to release c. auto release after 60 seconds 11. Fn: Function key (with LED status indicator: ON: Green, OFF: dark) WMP-248/249 User’s manual...
Page 29
Side View Standard model without Customized model with door DVD (or Smart card reader) Rear View WMP-248 (Fan) WMP-249 (Fanless) WMP-248/249 User’s manual...
Page 30
I/O parts (Standard version) I/O parts (Isolated version) isolation isolated COM 4KV isolated RS-232 x 1, RS-232/422/485 x 1 isolated USB 4KV isolated USB 2.0 x 1 (Full speed) isolated LAN 4KV isolated Lan x 1 (Gigabit) WMP-248/249 User’s manual...
<PgUp> and <PgDn> keys to change entries, <F1> for help and <Esc> to quit. When you enter the Setup utility, the Main Menu screen will appear on the screen. The Main Menu allows you to select from various setup functions and exit choices. WMP-248/249 User’s manual...
Page 33
This section provides information on the BIOS information, and Battery information System Date Set the system date. Use the <Tab> key to switch between data elements. System Time Set the system time. Use the <Tab> key to switch between time elements. WMP-248/249 User’s manual...
Page 34
Wake system with Dynamic Time Enables or disables system wake on alarm event. When enabled, the system will wake on the current time+Increase minute(s). Trusted Computing Security Device support Enables or disables BIOS support for security device. WMP-248/249 User’s manual...
Page 35
Software Feature Mask Configuration RAID OROM/RST driver will refer to the SWFM configuration to enable or disable the storage features. Info Report Configuration System configuration information report. It includes Post report/Error message report/Summary report USB Configuration WMP-248/249 User’s manual...
Page 36
Set Parameters of Serial Port 5. Serial Port 6 Configuration Set Parameters of Serial Port 6. Intel(R) Smart Connect Technology ISCT Support Enable/Disable Intel Smart Connect ISCT Notification Control Enable/Disable ISCT notification control ISCT WLAN Power Control Enable/Disable ISCT power control WMP-248/249 User’s manual...
Page 37
Number of minutes to keep lock status. 0 means lock always.1~100 minutes mean lock hold time. Power key Vol+/- key Backlight+/- key Reading light key Display switch key LCD backlight key Lock key Fn key Enable/Disable relative key function WMP-248/249 User’s manual...
Page 38
Chipset System Agent (SA)/PCH-IO Configuration This screen provides information on System Agent and PCH parameters. PCH-IO Configuration PCH parameters WMP-248/249 User’s manual...
Page 39
Disabled displays normal POST message. Hard Drive BBS Priorities Set the order of the legacy devices in this group CSM16 Parameters Enable/Disable option ROM execution settings, etc. CSM parameters Option ROM execution, boot options filter, etc. WMP-248/249 User’s manual...
Page 40
Security Enables or disables the security chip. It is recommended that you use this function with the Administrator/User password. WMP-248/249 User’s manual...
Page 41
Save the changes done so far as User Defaults. Restore User Defaults Restore the User Defaults to all the setup options. Launch EFI Shell From filesystem device Attempts to Launch EFI Shell application (Shellx64.efi) from one of the available filesystem devices. WMP-248/249 User’s manual...
A. Jumper settings and Connectors This appendix gives the definitions and shows the positions of jumpers, headers and connectors. All of the configuration jumpers on WMP-248/249 are in the proper position. Note: Some of jumpers or connectors will be removed base on system configuration.
Page 43
+1.35VS OPEN (default) +1.5VS JP9 –Touch Panel Type Selection Description Jumper Setting 3M type 1-2, 3-4 (default) ELO type 5-6,7-8 JP10 –SATA or SATA DOM Selection Description Jumper Setting SATA DOM 1-2 ---power +5V SATA 2-3(default)--- GND WMP-248/249 User’s manual...
Page 49
J9,J18 – PWM CPU FAN, SYSTEM FAN Signal Description Pin # J9(CPU) J18(SYSTEM) CPU PWM SYS PWM CPU RPM SYS RPM VCPUFAN VSYSFAN J10 – PWM CPU FAN Signal Description Pin # J10(CPU) 2.54mm VCPUFAN CPU RPM CPU PWM J11 – EC Reset WMP-248/249 User’s manual...
Page 54
+5VSB Data - Data + Ground Ground J25–Internal USB 5V Interface. Support EC control Disable/Enable USB Function Pin # Signal Description +5VSB +5VSB Data - Data + Ground Ground J21 – mini PCI Express / mSATA Socket WMP-248/249 User’s manual...
Page 57
+3.3VSB J24 – POWER & HDD LED Pin # Signal Description SATA LED# +3.3VSB +3.3VSB Power LED# J28 – CAP Front Bezel Button Connector Pin # Signal Description +5VSB +3.3VSB KP_SCL KP_SDA PWR_LED# Programmable_LED SATA_LED# Ground Ground WMP-248/249 User’s manual...
Page 58
J29 – Standard SATA Interface Pin # Signal Description Ground Ground Ground J30 – Standard SATA / SATA DOM Interface Pin # Signal Description Ground Ground Ground / +5V J31 –BIOS SOCKET Pin # Signal Description Pin # Signal Description HOLD# WMP-248/249 User’s manual...
Similar color as WMP series 10 degree tilt down and 30 degree tilt up solution 5,000 times hinge life cycle Specifications: Weight Capacity: Max 10kgs Monitor Mounting Holes VESA 75*75mm or 100*100mm Application using Desktop stand WMP-248/249 User’s manual...
For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.wincomm.com.tw/contact.aspx Note: Follow the national requirement to dispose unit WMP-248/249 User’s manual...