Page 2
Version Change History Date Version Description Remark 2012/7/6 First release Cosa Huang 2012/8/20 Update battery spec James.Chiu 2013/3/6 1. Add in WMP-226V/227V James.Chiu models support Ivy bridge 2. Correct some error 2013/9/3 1. Add microphone on I/O James.Chiu cover as option in feature 2013/12/20 1.4 1.
Page 3
Acknowledgments Intel® 2nd/3rd generation Core i and Celeron are registered trademarks of Intel® Corporation. IBM, PC/AT, PS/2 are trademarks of International Business Machines Corporation. ® ® Microsoft Windows is a registered trademark of Microsoft Corporation. RTL is a trademark of Realtek Semi-Conductor Co., Ltd. ...
Page 4
FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy.
Safety Instructions Intended use The WMP-226(V)/227(V) is intended to serve as a medical monitor which is designed for general purpose for hospital environment and for diagnosis. It could be used for Surgical, Radiology, PACS (Picture Archiving Communication Systems), LIS (Lab Information Systems) and Electronic Medical Record purpose.
Page 6
If the medical panel PC unit does fall to the ground, immediately turn the power off and disconnect cords. Then contact a service technician for repairs. Continual use of the unit may result cause a fire or electric shock. Also, do not repair the unit on your own.
Page 7
If the unit is not going to be in use for an extended period of time, remember to disconnect the unit. The medical panel PC unit uses voltage between 100-240VAC. Connect the unit to a power source with the same numerical value as shown. Please use only the power cord provided by the dealer to ensure safety and EMC compliance.
Page 8
Cleaning the unit Remember to turn off the power source and to unplug the cord from the outlet before cleaning the unit. Carefully dismount the unit or bring the unit down from suspension to clean. Please use a dry soft cloth to clean the unit. Take a dry cloth and wipe the unit dry.
Page 9
parts. If unauthorized parts are used it may result in starting a fire, electrical shock and/or other dangers. ISO 7000-0434 : Caution, consult ACCOMPANYING DOCUMENTS. ISO 7000-1641 : Follow operating instructions or Consult instructions for use. IEC 60417 -5009 : STAND-BY. IEC 60417-5031 : Direct current.
Page 10
When networking with electrical devices, the operator is responsible for ensuring that the resulting system meets the requirements set forth by the following standards: – EN 60601-1 (IEC 60601-1) Medical electrical equipment Part 1: General requirements for safety – EN 60601-1-1 (IEC 60601-1-1) Medical electrical equipment Part 1-1: General requirements for safety Collateral standard: Safety requirements for...
C) Caution: This adapter Sinpro MPU101-105 is a forming part of the medical device Contact information: 3F, No.14, Prosperity Road II, Science-Based Industrial Park, Hsinchu, Taiwan 300, R.O.C TEL: (886) 3 5780000 E-Mail: Sales@wincomm.com.tw WMP-226(V)/227(V) User’s manual...
Introduction Product Description The WMP-226(V)/227(V) Medical Panel PC are based on Intel 2nd/3rd generation Core i processor which can deliver faster graphic with higher CPU performance. It accommodates one 2.5” SATA III hard disk drive and up to 8GB DDR3 SODIMM. The high brightness LCD, Low noise (WMP-226(V)) / Fanless (WMP-227(V)) solution, integrated multimedia functions and extensive expansion options make them the perfect platform...
Package list Before you begin installing your Medical Station, please make sure that the following items have been shipped: The WMP-226(V) or WMP-227(V) Medical Panel PC unit One DVD containing user manual, chipset drivers Power Adapter x 1 (Mf:Sinpro, type/model: MPU101-105) ...
Features Seamless on the front side Easy wipe surfaces with no internal corners 21.5" (1920X1080) Diagnostic Panel High performance Intel 2nd/3rd generation Core i series mobile CPU Two mini PCI-e expansion HDD Anti-vibration mechanism ...
Page 17
170°(H) Viewing Angle 160°(V) Operating 0°C~ 40°C (32°F~104°F) Temperature Brightness Control Cautions: Continuous displaying fixed pattern may induce image sticking. It’s recommended to use screen saver or moving content periodically if fixed pattern is displayed on the screen. Power Adapter Specifications Power Close-frame Sinpro...
Operating: 15g/0.53 oz, 11 ms, half sine wave Vibration Non-operating: 50g/1.76 oz, 11 ms, half sine wave Operating: 5 ~ 17 Hz , Amplitude:0.117 ~ 500Hz , Shock Acceleration:1.0G Non-operating:10~55Hz/0.15g, 55~500Hz/2.0g Operational: up to 3000 m (9842 feet) Altitudes Shipping: up to 12192 m (40000 feet) 700 –...
Page 19
Electromagnetic environment – Emissions test Compliance guidance RF emissions The model WMP-226(V)/227(V) uses RF energy only for its internal CISPR 11 function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. RF emissions The model WMP-226(V)/227(V) is suitable for use in all establishments,...
For transmitters rated at a maximum output power not listed above, the recommended separation distanced in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
interruptions <5 % UT <5 % UT Mains power quality should be that of a (>95 % dip in (>95 % dip in typical commercial or voltage hospital environment. variations for 0,5 cycle for 0,5 cycle If the user of the on power model supply...
Page 22
Portable and mobile RF communications equipment should be used no closer to any part of the model WMP-226(V)/227(V), including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance Conducted RF 3 Vrms d = 1,2 IEC 61000-4-6...
Cleaning/Disinfecting Steps: 1. Wipe the WMP-226(V)/227(V) with a dry clean cloth. 2. Prepare agent per manufacturer’s instructions or hospital protocol. Cautions: Do not immerse or rinse the WMP-226(V)/227(V) and its peripherals. If you accidentally spill liquid on the device, disconnect the unit from the power source.
Getting Started System Set Up The following is a summary of the steps in setting up the system for use. (1). You can fix the system to a mounting fixture using the screw holes on the sides of the system. (2).
System View Front View Webcam (optional) Hotkey and LED definition at front panel Located on Touch screen bottom side, from left to right, front view 1-1. Up. HDD: Yellow 1-2 Down. Battery: AC mode: Dark Battery mode: Yellow Battery low: Yellow blinking 2.
Page 28
8. Clean me (with LED status indicator: ON: Yellow, OFF: dark) a. Keep on contacting 5 seconds to active b. keep contacting 5 seconds to release c. auto release after 60 seconds I/O parts (WMP-226(V)/227(V)) WMP-226(V)/227(V) User’s manual...
BIOS Setup BIOS Introduction The AMI BIOS (Basic Input / Output System) installed in your computer system’s ROM supports Intel processors. The BIOS provides critical low-level support for a standard device such as disk drives, serial ports and parallel ports. It also adds virus and password protection as well as special support for detailed fine-tuning of the chipset controlling the entire system.
Page 31
Main This section provides information on the BIOS information, and Battery information System Date Set the system date. Use the <Tab> key to switch between data elements. System Time Set the system time. Use the <Tab> key to switch between time elements.
Page 32
Advanced ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration. Enable Hibernation Enables or Disables System ability to Hibernate (OS/S4 Sleep State). This option may be not effective with some OS. ACPI Sleep State Select the highest ACPI sleep state the system will enter, when the SUSPEND button is pressed.
Enabled for Windows XP and Linux (OS optimized for Hyper-Threading Technology) and Disabled for other OS (OS optimized for Hyper-Threading Technology) Active Processor Cores Number of cores to enable in each processor package. Limit CPUID Maximum When CPUID instruction is executed, newer CPU may return a value greater than 3 which causes certain problem with specific operating systems.
Page 34
This is typically required when the user wants to examine the physical parameters of the host adapters transmit PHY (eg examine the ‘eye’ on a scope or similar). IDE Legacy / Native Mode Selection. IDE Legacy / Native Mode Selection. Info Report Configuration System configration information report.
Page 35
Serial Port 5 Configuration Set Parameters of Serial Port 5. Serial Port 6 Configuration Set Parameters of Serial Port 6. WMP-226(V)/227(V) User’s manual...
Page 36
Chipset System Agent (SA)/PCH-IO Configuration This screen provides information on System Agent and PCH parameters. WMP-226(V)/227(V) User’s manual...
Page 37
Boot Setup Prompt Timeout Number of seconds to wait for setup activation key. 65535(0xFFFF) means indefinite waiting. Bootup Numlock State Selects the keyboard NumLock state. Boot Beep Enables or disables boot status beep Quiet Boot Allows you to determine whether to display the Logo at system startup.
Page 38
Security Enables or disables the security chip. It is recommended that you use this function with the Administrator/User password. WMP-226(V)/227(V) User’s manual...
Page 39
Save & Exit Save Changes and Exit Exit system setup after saving the changes. Discard Changes and Exit Exit system setup without saving any changes. Save Changes and Reset Reset the system after saving the changes. Discard Changes and Reset Reset system setup without saving the changes.
APPENDIX Appendix A. Jumper settings and Connectors This appendix gives the definitions and shows the positions of jumpers, headers and connectors. All of the configuration jumpers on WMP-226(V)/227(V) are in the proper position. Note: Some of jumpers or connectors will be removed base on system configuration.
Page 42
APPENDIX JP10 – CMOS Clear Description Jumper Setting Normal Open 1-2 (default) CMOS Clear JP11 – Thermal sensor Description Jumper Setting Auto detect 1-2(default) always 25 ℃ always -40 ℃ JP12 – SATA or SATA DOM Selection Description Jumper Setting SATA DOM 1-2 ---power +5V SATA...
Page 43
APPENDIX Connector Definition PJ5 – HDD Power Connector Pin # Signal Description +12V Ground Ground PJ6 – HDD Power Connector Pin # Signal Description +12V Ground Ground PJ7 – Battery Connector Pin1 Pin # Signal Description BATT+ BATT+ WMP-226(V)/227(V) User’s manual...
Page 44
APPENDIX BATT+ BAT_T BAT_C BAT_D BATT_EN# BATT- BATT- BATT- PJ8 – Power Jack Connector Pin # Signal Description DC In DC In Ground Ground Ground J5,J6,J7 – Internal USB +3.3V Interface Pin # Signal Description +3.3VS Data - Data + Ground Ground WMP-226(V)/227(V) User’s manual...
Page 51
APPENDIX J23 H9.2 Near CPU J24 H5.2 Near External Symbol Symbol Symbol Symbol Symbol Symbol VREFDQ DQ27 DQS4 DQ31 DQ38 CKE0 DQ34 DQ39 DQ35 DQS0# DQ44 DQ40 DQS0 NF/A14 DQ45 DQ41 DQS5# DQS5 DQ42 DQ12 DQ46 DQ43 DQ13 DQ47 DQS1# DQ48 DQ52 DQS1...
Page 54
APPENDIX +3.3V Sound Volume Up Sound Volume Down Ground LCD BackLight Up LCD BackLight Down Touch Screen Forbid LCD BackLight ON/OFF J30 – PS2 KB/MS connector Pin # Signal Description Keyboard data Mouse data Keyboard clock Mouse clock J31 – Light Sensor Connector (For Outdoor) Pin # Signal Description Light Sensor...
Page 55
APPENDIX J32 – EC Reset Pin # Signal Description VCC_POR# J33 – HEATER, CLEAR ME LED INDICATE Pin # Signal Description +3.3V_UC HEATER_LED# KEYLOCK_LED# J34, J36 – Standard SATA Interface Pin # Signal Description Ground Ground Ground WMP-226(V)/227(V) User’s manual...
Page 56
APPENDIX J35 – RS-232 TTL Connector Pin # Signal Description Pin # Signal Description DCD# DSR# RTS# SOUT CTS# DTR# +5VS J46,J37 – COM3, COM4 Serial Port Pin # Signal Description Pin # Signal Description 232_DCD 232_DSR 232_SIN 232_RTS 232_SOUT 232_CTS 232_DTR 232_RI...
Page 57
APPENDIX J41 – POWER & HDD LED (For WMP-176/196 ) Pin # Signal Description SATA LED +3.3V +3.3V Power LED J42 – ATX 12V Connect (For Heater Power) Pin # Signal Description +12V +12V Ground Ground J43 , J45 – Passive Speaker Connect J43(Right Channel) J45(Left Channel) Pin #...
Page 58
APPENDIX J44 – Handset Connect Pin # Signal Description HOOK_ON# Handset speaker Handset MIC J47 – Power Switch connect Pin # Signal Description Power ON J48, J49 – Ethernet Port Pin # Signal Description Data0+ Data0- Data1+ Data2+ Data2- Data1- Data3+ Data3- WMP-226(V)/227(V) User’s manual...
Page 59
APPENDIX J50, J51 – USB1/2,3/4 Port Pin # Signal Description Data- Data+ J52 – DVI-I Interface Pin # Signal Description Pin # Signal Description TMDS Data2- TMDS Data2+ TMDS Data2 shield DDC Clock DDC Data Analog VSYNC TMDS Data1- TMDS Data1+ TMDS Data1 Shield Hot Plug Detect TMDS Data0-...
Page 60
APPENDIX J53,J54 – Audio Connector Pin # Signal Description Microphone (stereo) Pink Line Out (stereo) Green J55 – Reset connector Pin # Signal Description SYS_RESET# J56 – Reset Button Pin # Signal Description SYS_RESET# J57 – COM1 Connector WMP-226(V)/227(V) User’s manual...
Page 61
APPENDIX Signal Description Pin # RS-232 RS-422 RS-485 Carrier Detect Transmit Data - Transmit Data - Receive Data Transmit Data + Transmit Data + Transmit Data Receive Data + Data Terminal Receive Data - Ready Ground Data Set Ready Request to Send Clear to Send Ring Indicator J58 –...
APPENDIX B. L type Stand (optional kit) Key Features and Benefits Similar color as WMP series 10 degree tilt down and 30 degree tilt up solution 5,000 times hinge life cycle Specifications: Weight Capacity: Max 10kgs Monitor Mounting Holes VESA 75*75mm or 100*100mm Application using Desktop stand...
APPENDIX C. Battery Pack Specifications (optional kit) Battery Model133 BP-WMP001-22/1900A Battery Type Li-ion 2S2P Minimum Capacity 3800 mAh Nominal Voltage 7.3 V Max. Charge Voltage 8.4V Cut Off Voltage 6.0v Suggested Charge Current (Max.) System Continuous 16.6 A Discharging Current (Max.) The End of Charge 150 mA/min...
APPENDIX D. Change Win Xp resolution to 1920*1080 1. Please help to follow below step to change setting 2. In display properties settings advanced monitor disable hide mode …screen resolution will have 1920*1080 resolution can use. WMP-226(V)/227(V) User’s manual...
APPENDIX E. How to disable battery when system hang up -WMP-226(V)/227(V) 1. When system hang up ,press power button 10 seconds to turn off system . If you can’t power on system by power button. Please follow below step to reset system. 2.
For the computers that are no longer useful or work well, please contact with worldwide distributors for recycling. The worldwide distributors show on the following website: http://www.wincomm.com.tw/contact.aspx Note: Follow the national requirement to dispose unit WMP-226(V)/227(V) User’s manual...
Need help?
Do you have a question about the WMP-226(V) and is the answer not in the manual?
Questions and answers