9.2.6 Platen Pressure Rolls
Adjustment
1.
Remove the printer cover, the platen, and the
paper deflector.
2.
Reinstall the platen.
3.
Open the pressure rolls with the paper release
a
(push the lever to the rear).
4.
Check for a minimum of 0.040 inch (1.02
mm) between the platen and the pressure
rolls at points
m,
Ii,
m
and
II .
5.
If there is insufficient clearance at any of the
points (
III ' B,
m '
or
m ),
adjust the
pressure roll arm
Ii
nearest to the out-of-
tolerance point.
6.
Check the adjustment of the end-of-forms
switch (9.2.17).
7.
Remove the platen.
8.
Reinstall the paper deflector, platen, and
printer cover (9.2.1).
9-18