Transducer - IBM System/32 Introduction And Maintenance Manual

Table of Contents

Advertisement

4.6.20 Transducer
Removal
1.
Open the printer cover.
2.
Remove the type belt (4.6.13).
3.
Unplug the transducer plug (P5). If P5 is
a 4-position plug, remove transducer ter-
minals 1 and 2.
4.
Remove the type belt guide roller by re-
moving one screw
m .
5.
Loosen the transducer mounting screw(s)
III
and remove the transducer from the
rear of the belt guard.
Replacement
1.
Replace in the reverse order of removal.
Place the brown wire in 1, black in 2 on
P5.
2.
Perform the transducer adjustment
(4.6.19).
Plastic Pad
(metal blades
only)
4-118