Descriptions Registry - Siemens Insys 56k Operating Manual

Slim dial-up modem
Table of Contents

Advertisement

S- Registry
Register
Function
S39*
Flow control
S40*
General settings
S41*
General settings
S46*
V.42bis Data Compression
S48*
Setting for V42 declaration phase
S86
Error event code
S91*
Transmit Level
S95*
Result code
*
These registries are saved in the EEPROM together with the AT&W command.
8.2
Description S Registry
Note:
Registries marked with *) are stored in the user defaults with
the command AT&W- Befehl.
S0*
Rings to Auto Answer:
Number of rings until the modem goes off-hook
For S0=0 the modem will not go off-hook when a call comes in. The value of S0
can be between 0 and 5.
S1
Ring Counter
Counter for call ringing. S1 is read-only. S1 will be reset to zero, when the modem
answers a call.
S2*
Escape Character
Escape character that causes the data mode to switch to online command input
mode. Values larger than 127 will lead to the fact that no ESC character will be
recognized.
S3
Carriage Return Character
Carriage Return Character.
56
Pocket Modem 56k
Units
Range
Default
-
3
-
104
-
195
-
138
-
7
-
Read-only
-
0-15
9
-
0
Dezember 05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents