7. Troubleshooting

7. Troubleshooting
Description
It is not possible to establish a
connection between the EFOY fuel
cell and the computer.
Commands are not accepted.
Operating parameters cannot be
modified.
Solution
Connect the EFOY unit to a functional battery.
Configuration is possible only if power is flowing to the
EFOY unit.
Check to see whether the data line and the interface
adapters are connected (see 4.2 Connection to the
Computer)
Check the configurations in terminal program (see
Chapter 4.3 Setting Up the Terminal Program.
Make sure the interface adapter is connected to the
allocated port (such as COM 1).
Check whether a connection has been established by
the terminal program.
If using a USB-RS232 adapter:
Make sure you have the correct COM port allocation (it
generally isn't a COM1 port). You can check the port in
your PC's Device Manager.
Check whether the USB adapter has been properly
installed and the PC recognizes it.
Enter commands only in upper case, i.e. SFC, and make
sure that you have spelled them correctly (see Chapter
6.2 Permissible Ranges of Operating Parameters).
Make sure that the desired value is within the
permissible range (see Chapter 6.2 Permissible Ranges
of Operating Parameters).