6. Additional Information
Miscellaneous Criteria
Reaction time
Energy
(maximal output energy)
Altitude of site
Capacity of battery
The reaction time must
elapse before the EFOY
unit reacts. For example,
switch-on voltage must
remain at 12.3 volts for at
least ten seconds before
the EFOY unit switches on
(factory settings).
If the switch-off criteria,
voltage and current, have
not been satisfied, the
EFOY unit will shut off
after generating the
number of watt-hours for
which it is set. (Example:
1200 watt-hours for the
EFOY 1200. Once the
switch-on criterion has
been satisfied, the EFOY
unit will go back on,
which can be immediately
afterwards.
No effect on EFOY fuel cells
No effect on EFOY fuel cells
29
If you are going to briefly use
high voltage appliances,
coordinate this value with
the times of operation.
This switch-off criterion
prevents unlimited charge
cycles caused by things like
defective batteries.