EFOY 600 User Manual page 21

Interface adapter ia1
Hide thumbs Also See for 600:
Table of Contents

Advertisement

5. Data Port Commands
Command
LIMITS↵
SFC↵
Output in the terminal program
Displays the permissible range for all operating
parameters. You will find information about the
parameters in Chapter 6.1 Explanation of Operating
Parameters
Example:
SFC>LIMITS↵
switch on voltage: min 11.0V max 13.0V
switch off voltage: min 13.5V max 14.7V
switch off current: min 0.5A max 10.0A
reaction time: min 1s max 300s
maximal output energy: min 50Wh max 3000Wh
altitude of site: min 0m max 2000m
capacity of battery: min 40Ah max 200Ah
SFC>
Permits monitoring of the current operating status by
displaying the various parameters. The EFOY unit
transmits a largely unformatted string with all available
parameters and their current value.
The parameters are described in Chapter 6.3.
Example:
SFC>SFC↵
battery voltage: 12.08V
output current: 0.0A
operating time: 5.8h
operating state: error
operating mode: auto
change cartridge
cartridge level below sensor
SFC>
21