Switch-on parameters
Operating Parameter
Switch-on voltage
Switch-off Parameters
The EFOY fuel cell switches off fully automatically. Controlling the shut-off are the two
operating parameters, battery voltage and charging current. In order for EFOY fuel cells to
shut off, the switch-off voltage must be exceeded and the current must be lower than the
shut-off point. The factory settings are 14.2 volts and 2 A respectively, meaning that the
EFOY fuel cell shuts off as soon as battery voltage exceeds 14.2 volts and charging current is
lower than 2 A.
Operating parameter
Switch-off voltage
Switch-off current
6.1

Explanation of the Operating Parameters

Function
The EFOY unit switches
on and charges the
battery when a
predetermined voltage
level is reached.
Function
Once the battery reaches
a predetermined voltage,
the EFOY unit will switch
off, provided that the
"switch-off current"
parameter is also met.
The EFOY unit will shut
off once current dips
below this level.
28
Note
A setting that is too high will
cause the EFOY unit to
switch on frequently.
Note
Please note your battery's
end-of-charge voltage.
Follow the manufacturer's
recommendations.
If you wish to use battery
voltage as the sole switch-
off parameter, set for
10000mA since EFOY fuel
cells will always produce a
lower value.