Permissible Ranges Of Operating Parameters - EFOY 600 User Manual

Interface adapter ia1
Hide thumbs Also See for 600:
Table of Contents

Advertisement

6. Additional Information
Operating parameter 12 V
Switch-on voltage
Switch-off voltage
Switch-off current
Reaction time
Energy
maximum output energy
* EFOY 600: 600 Wh; EFOY 900: 900 Wh; EFOY 1200: 1200 Wh; EFOY 1600: 1560 Wh
Operating parameter 24 V
Switch-on voltage
Switch-off voltage
Switch-off current
Reaction time
Energy
maximum output energy
**EFOY 1600 24V: 1560 Wh
6.2
Permissible Ranges of Operating
Factory
setting
12300 mV
14200 mV
2000 mA
10 seconds
Depends on
EFOY
model*
Factory
setting
24600mV
28200mV
2000 mA
10 seconds
1560 Wh**
30
Parameters
Min.
Max.
11000 mV
13000 mV
13500 mV
14600 mV
500 mA
10000 mA
1 second
300
seconds
50 Wh
3000 Wh
Min.
Max.
22000mV
26000mV
27000mV
29400mV
500 mA
10000 mA
1 second
300
seconds
50 Wh
3000 Wh