5. Data Port Commands
Command
STDVALUE↵
VALUE↵
VER↵
Output in the terminal program
Displays the standard default settings of all operating
parameters on the terminal interface but does not set
them for actual operation. If they are desired, use the
DEFAULT command.
Example:
SFC>STDVALUE↵
switch on voltage: 12.3V
switch off voltage: 14.2V
switch off current: 2.0A
reaction time: 20s
maximal output energy: 1200Wh
altitude of site: 500m
capacity of battery: 50Ah
SFC>
Displays the current set of operating parameters
without modifying them.
Example:
SFC>VALUE↵
switch on voltage 12.3V
switch off voltage 14.2V
switch off current 2.0A
reaction time 20s
maximal output energy 1200Wh
altitude of site: 500m
capacity of battery: 50Ah
SFC>
Indicates the firmware version.
Example:
SFC>VER↵
Firmwareversion A50-1 4.03L12V date 2005-08-31
SFC>
22