Check the followinglist to be sure a service call is reatly necessary. A quick reference
of this manual, as well as reviewing additional information on items to check, may
prevent an unneeded service call.
If nothing on the range operates:
• check for a blowncircuitfuse or a tripped main circuit breaker.
• check if rangeis propertyconnectedto electric circuit in house.
If ventilation fan does not operate but everything else on the
range does:
• check behindlower access door if power cord to blowerassemblyhas
been disconnected.
If grill or surface burner fails to light:
• check to be sure unit is properly connected to power supply.
• check for a blown circuit fuse or a tripped main circuit breaker.
• check to be sure burner ports or ignition ports are not clogged.
• check to be sure regulator is set for the correct fuel
• check to be sure inlet pressure is adequate.
• clean igniter (see p. 22).
If the flame is uneven:
• burnerportsmay be clogged.
• frame settingmay need to be adjusted (see pg. 10-11).
If grill or surface burner flame lifts off the ports:
• shutter on the mixer tube needs to be closeduntilflames settle on the
burner ports(see p. 10 ).
If grill or surface burner flame is yellow in color:
• shutteron the mixertube needs to be opened until yellow disappears(see
p, fo).
If ventilation system is not capturing smoke efficiently:
• check on crossventilationin room or make up air.
• excessiveamountof smoke is being created; check instructions for
grilling,trimmingmeats (see p. 18).
• outsidewa_ cap may be trapped shut.
• range may be improperly installed; check ducting information (see p. 47).
• air filter may be improperly installed (see p. 13).