7. Timing chart

● ● ● ● Horizontal timing (common to each operation mode)
L VAL
D VAL
V ide o ou t
1CLK
LIN E1
F S3 0 0AC L
B ayer arr ay
LI N E2
Communication command: H'10 (1××0××××)
● ● ● ● Vertical
Vertical timing / Continuous shutter Normal scan
Vertical
Vertical
FVAL
V ide o o ut
Communication command: H'10 (1××00×××)
● ● ● ● Vertical
Vertical timing / Continuous shutter Normal scan
Vertical
Vertical
FVA L
Vid eo out
Vert ical
blan king
Communication command: H'10 (1××01×××)
Hor i zon tal blan kin g
1 3 2C LK
R1
Gr 1
R2
...
・ ・ ・
G b1
B1
Gb2
...
1234・・・
31H
Ve rtical
bl anking
H'11 (×××0×000)
5 00H
6H
V ideo ou tput ac tive te rm
H'11 (×××0×000)
3 0 f ps :1clk =
6 0 f ps :1clk =
9 0 f ps :1clk =
Vi deo out put acti ve term
6 48C L K
O ne hor i zon tal p eri od(1 H)
78 0CLK
Gr 2
R3
Gr 3
...
...
B3
G b3
B3
...
...
Blanking Compression OFF
・ ・ ・ ・
30 fps :1H =
63.5556usec, 29.9700Hz
60 fps :1H =
31.7778usec, 59.9400Hz
90 fps :1H =
21.1852usec, 89.9100Hz
525H
One ver tical p eriod(1 V)
494
493
494H
Vid eo outp ut acti ve term
Blanking Compression ON
・ ・ ・ ・
30 f ps :1H =
63.5556usec, 31.4685Hz
60 f ps :1H =
31.7778usec, 62.9370Hz
90 f ps :1H =
21.1852usec, 94.4055Hz
One vertic al peri od(1V)
494H
- 19 -
N10316;19/36
81.4816nsec
40.7408nsec
27.1605nsec
31H
6H