Module Jig Service Concept - Nokia 6111 RM-82 Service Manual

Mobile terminal
Hide thumbs Also See for 6111 RM-82:
Table of Contents

Advertisement

RM-82
Service tools and concepts
The following equipment is required for the AMS SW update when the system module is placed in the module
jig MJ-58 and connected through a prommer set-up:
Item
Type
1
MJ-58
2
CA-41PS
3
XCS-4
4
FPS-10
5
AC-33
6
CA-31D
7
PKD-1
8

Module jig service concept

This concept is for troubleshooting and RF calibration.
MJ-58 is intended for use with an external power supply.
MJ-58 input voltage: normal +4 V, maximum +6.5 V.
Ensure that the jumper is set for voltage regulation before the external power supply is connected.
When a prommer is used for power supply (4 V), the jumper should be set to bypass regulator.
EM calibrations including Zocus are only done with JBV-1. Module jig MJ-58 does not support Zocus calibration.
Issue 1
Figure 82 Module jig flash concept with FPS-10
Description
Module jig
Power cable
Modular cable
Flash prommer box
AC charger
USB cable
Software protection key
Computer with Phoenix SSW
COMPANY CONFIDENTIAL
Copyright © 2005 Nokia. All rights reserved.
Nokia Customer Care
Page 4 –23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents