Download Print this page

Marani CLP-2600 User Manual page 36

Digital speaker processor

Advertisement

Led Meter Bars
The CLP2600 has on its front panel 10 led meter bars, able to show constantly the overall status
of the processed signals.
Logically, the led meter bars can be divided in 2 different blocks:
Led Meter Bars for the Clip/Input level displaying
1.
Led Meter Bars for the Limiter/Output level displaying
2.
Led Meter bars for the Compressors activity displaying
3.
Referring to the following pictures
Clip/Input Led Meter Bars
Limiter/Output Led Meter Bars
Led Meter Bars for the Clip/Input : these bar of led meters is showing, when turned on the Clip
led, an occurring Clip on the input signal, with the other leds is showing the current input level
BEFORE ANY PROCESS, ranging from +20dBu (Clip) up to -20dBu.
Led Meter Bars for the Lim/Output : these bar of led meters is showing, when turned on the
Lim led, that the Peak Limiter is active and limiting the output signal, with the Clip led an
occurring Clip on the output signal and with the other leds is showing the current output level
AFTER ALL PROCESSES, ranging from +20dBu (Clip) up to -15dBu.
Left Channel Compressor
Activity Led Meter Bars
Led Meter Bars for the Compressors Activity : these bar of led meters is showing from top to
down the activity of the RMS Compressors.
When not active, the +20dBu led will be turned on orange, when the activity is present, its
amount is shown from top to down by the leds, ranging from +20dBu up to -10 dBu.
GND LIFT switch
When the switch is positioned on GND, the Main Power Supply GND is connected to the Chassis.
Cmp1
Cmp2
Cmp3
Cmp1
Lch
34
Cmp2
Cmp3
Rch
Right Channel Compressor
Activity Led Meter Bars