Attack Time [A]
in steps of 1ms - from 5ms to 20ms then 5ms - from 20ms to 30ms then 10ms - from 30ms to
100ms and 20ms - from 100ms to 200ms.
The Limiter's Attack Time can be adjusted by rotating the
Release Time [R]
steps of 0.1s and can be adjusted by rotating the
Limiter Active Threshold : the selectable range of the Peak Limiter's Threshold is from +20dB
(Limiter not active) to -10.0dB in steps of 0.2 dB and can be adjusted by rotating the
encoder.
Note: The Peak limiter Threshold is defined in Vp, due to the fact that with both, Sinusoid and
Squared wave testing signals, the CLP2600 Peak Limited output Vp (Peak-Peak) Level is the same
and matching the selected one.
Note1: once the desired options have been selected using the 3 encoders, they are automatically
saved as current and stored in the CLP2600 system status once leaving the page.
Note2: to exit this page, push the
I ti useful to underline that the Limiter implemented on the CLP2600 before the final output is a

PEAK LIMITER.

This kind of Limiter is acting on the Signal Peak detection and therefore the limitation is on the
output Peak value.
This kind of Limiter, working as illustrated by the picture here above, is useful for the amplifier's
and Loudspeakers' protection.
: the selectable range of the Peak Limiter's Attack Time is from 5ms to 200ms
: the selectable range of the Peak Limiter's Release Time is from 0.1s to 3s in
ESC
NAV/PM1
PM2
encoder.
button.
27
encoder.
PM3

Advertisement

loading