Electrical Wiring Connection - Daikin FHC20JEVLK Installation Manual

R22 split series
Table of Contents

Advertisement

IMPORTANT : * These values are for information only. They should be checked and selected to comply with local and/or
national codes and regulations. They are also subject to the type of installation and size of conductors.
** The appropriate voltage range should be checked with data label on the unit.
FHC20JEVLK - RD20JEVLK
FHC25JEVLK - RD25JEVLK
COMP
Indoor Unit
Terminal Block
L
N
Model
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended time delay fuse*
FHC30JEVLK - RD30JEVLK
COMP
Indoor Unit
Terminal Block
L
N
Model
Voltage range**
Power supply cable size*
Number of conductors
Interconnection cable size*
Number of conductors
Recommended time delay fuse*

ELECTRICAL WIRING CONNECTION

Interconnection Cable
Power Supply
Cable
Indoor
Outdoor
Indoor
Outdoor
2
mm
mm
2
A
Interconnection Cable
Power Supply Cable
Indoor
Outdoor
Indoor
Outdoor
mm
2
mm
2
A
1-13
COMP
L1
Outdoor Unit
Terminal Block
N1
L
N
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
FHC20JEVLK
RD20JEVLK
220V/1Ph/60Hz +
220V/1Ph/60Hz +
2.5
3
1.0
4
20
COMP
Outdoor Unit
Terminal Block
L
N
L
N
FHC30JEVLK
RD30JEVLK
220V/1Ph/60Hz +
220V/1Ph/60Hz +
4.0
3
2.5
4
30
FHC25JEVLK
RD25JEVLK
!
!
2.5
3
1.0
4
25
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
!