Split unit air conditioner
ceiling mounted c series; e series; fl-e series; fh-c series; fly-e series; fhy-c series
cooling only & heatpump [50hz] (78 pages)
CONTENTS 1. SAFETY PRECAUTIONS To gain full advantage of the air conditioner’s functions and to 1. SAFETY PRECAUTIONS....... 1 avoid malfunction due to mishandling, please read this opera- 2. WHAT TO DO BEFORE OPERATION... 3 tion manual carefully before use. 3.
Page 3
Otherwise, it may cause a fire or water leakage. Further- The use of any other power supply may cause heat gener- more, if an automatic restart control is provided against ation, a fire, or air conditioner failures. power failure and the power is recovered, the fan will rotate Consult your local dealer regarding what to do in case suddenly and may cause injury.
High-place work is required, to which utmost attention must CAUTION! DANGER OF ELECTRIC SHOCKS be paid. • Shut off power supply before work. If the scaffold is unstable, you may fall or topple down, thus • Never open the control box lid for 10 minutes causing injury.
Page 5
Names and functions of parts OUTDOOR INDOOR Multi system Unit with remote controller NOTE • Read the operation manual attached to the Indoor unit remote controller you are using. Outdoor unit When using a wireless remote controller, refer to the Air discharge operation manual attached to the wireless remote Horizontal blade (at air discharge)
3. OPERATION RANGE HEATING [°C]* If the temperature or the humidity is beyond the fol- INDOOR OUTDOOR OUTDOOR UNIT lowing conditions, safety devices may work and the TEMPERATURE TEMPERATURE – 15 to 24 air conditioner may not operate, or sometimes, RXS35/50/60 10 to 30 –...
Regarding wiring • If the COOLING OPERATION is used when the indoor temperature is low, frost forms on the heat • All wiring must be performed by an qualified exchanger of the indoor unit. This can decrease personnel. the cooling capacity. In this case, the air condi- To do wiring, ask your local dealer.
Page 8
• After maximum 10 minutes of the DEFROST • If the PROGRAM DRY OPERATION is used OPERATION, the air conditioner returns to the when the indoor temperature is low, frost forms HEATING OPERATION. the heat exchanger of the indoor unit. In this case, •...
MOVEMENT OF THE HORIZONTAL BLADE B. LEFT AND RIGHT DIRECTION For the following conditions, micro computer con- • The left and right airflow direction can be fixed at trols the airflow direction so it may be different from the desired position manually. the display.
• Turn off the power circuit breaker when it is not in CAUTION use for a long period. When the power circuit • Do not wash the air conditioner with water. breaker is turned on, small amount of power is It may cause electric shocks or a fire due to leak- consumed even if the air conditioner is not in oper- age.
Page 11
2. Take out the air filter. HOW TO CLEAN THE SUCTION GRILLE Push up the knobs at 2 places and take out the 1. Open the suction grille. air filter. Slide the knob to the arrow direction and slowly open the suction grille. Knob Knob Knobs...
Page 12
4. Clean the suction grille. CLEANING BEFORE AND AFTER SEA- Wash the suction grille with water or neutral SONAL USE detergent using a soft brush and then dry it. STARTING AFTER LONG STOP PERIOD Confirm the following • Check that the air inlet and outlet of indoor and outdoor unit are not blocked.
Turn off the power circuit breaker. If the OPERATION lamp lights, the air condi- • During the power circuit breaker is turned on, tioner is in normal condition. some watts of electricity is being used even if the It does not restart immediately because a air conditioner is not operating.
Page 14
II. THE OPERATION SOMETIMES STOPS • The airflow direction display of the remote controller differs from the actual • The remote controller displays “U4” and operation of the horizontal blades. “U5”, and the operation stops. However, it will restart in a few minutes. <COOL AND PROGRAM DRY OPERA- TIONS>...
• A low continuous flow “Shuh” sound • Read through characteristics of the which is heard when the air conditioner is COOLING OPERATION, characteristics of in the COOLING or DEFROST OPERA- the HEATING OPERATION, and character- TION or a trickling sound which is heard istics of the PROGRAM DRY OPERATION when the air conditioner is in the on page 6-7.
Page 16
3. The air conditioner operates but it does not 4. Operation was performed or stopped sufficiently cool or heat. although the ON/OFF button was not pressed. • Check if the air inlet or outlet of outdoor or indoor unit is blocked by obstacles. •...
Menu/Enter button. •The error code blinks and the contact Error Code:A1 address and model name will appear. Contact Info •Notify your Daikin dealer of the Error code 0123 – 4567 – 8900 and Model name. ––– /000 Indoor Model –––...
Need help?
Do you have a question about the FHA35AVEB and is the answer not in the manual?
Questions and answers